- 50 -
Burner
(
Ø
in mm)
Gas type
Gas
pressure
(mbar)
Nozzle
marking
(1/100 mm)
Gas
consump-
tion
Power
(kW)
MAX MIN
Standard
burner
Ø 75
Liquefied
gas
G30/G31
50
58
127 g/h
1,75 0,44
28-30/37
68
Natural gas
G20
20
98
167 dm³/h
G25
100
194 dm³/h
Strong
burner
Ø 100
Liquefied
gas
G30/G31
50
75 S
218 g/h
3,00 0,75
28-30/37
88
Natural gas
G20
20
116
286 dm³/h
G25
134
332 dm³/h
Triple
ring
burner
Ø 130
Liquefied
gas
G30/G31
50
77
277 g/h
3,80 1,80
28-30/37
98
Natural gas
G20
20
137
363 dm³/h
G25
152
421 dm³/h
5. Installation and operation
5.1 Installation instructions
CAUTION!
Any installation, connection and maintenance related to the device can be
performed only by a qualified, certified technician, according to international,
national and local laws.
Unpack the device and remove
the packing material, according
to the environmental
regulations.
Mount the supplied feet by
screwing them into the designed
holes under the device (Fig. 2)
Fig. 2