5.1.5 Electrical connections
DANGER! Electric shock hazard!
The device can cause injuries due to improper installation!
Before installation and connecting the local power grid specification should
be compared with that of the device (see rating plate). Connect the device only
in case of compliance!
Before connecting the device to the electricity network ensure that the voltage and
frequency values given on the rating place match those of the existing electrical
installation.
Voltage tolerance is ± 10%.
The connection to the electricity network must conform to all international, domestic
and local regulations.
The device is equipped with a 3 x 1.5 mm
2
cable with plug.
The socket's electrical circuit must be secured to a minimum of 16A. Only connect
the device to a wall socket; do not use extension cords or power strips to avoid the
risk of overheating and fire.
Locate the device so that the plug is easily accessible for the device to be quickly
disconnected if the need arises.
5.1.6 Gas connection
The device has been produced and verified for use with the type of gas given on the
rating plate. Ensure before installation that the local gas source (type and pressure)
are compliant with the device's parameters.
At the place of installation which is publicly accessible, accident prevention
regulations and safety rules in case of fire and panic must be observed.
A certified gas shut-off valve must be installed at the gas connection, in the easily
accessible place between the gas supply network and the device, to be able to shut
the gas supply off at any moment if necessary.
The gas connection is located at the rear of the device.
The connection to the gas supply network or gas container can be performed using
various types of hoses (metal or rubber hose).