background image

INSTRUCTIONS

INSTRUCTIONS

INSTRUCTIONS

INSTRUCTIONS

INSTRUCTIONS

- The appliance runs on BUTANE or PROPANE gas at 30 mbars.
- The appliance and gas cylinder have to be placed on a flat surface in places far from

inflammable materials.

- Protect  the cylinder and the appliance from direct sunlight
- Cylinder must not be kept in the home, in an airless interior or underground
- ATTENTION: do not move the appliance when in use or when it is still warm.
- Change gas pipes that have deteriorated and replace them before the expiry date

imprinted on the pipe. Pipes must not be dented in any parts and must be installed in
such a way that they do not have to be placed under any strain. THEY MUST NOT
COME INTO CONTACT with any hot part.

- Repairs and maintenance shall be performed by skilled staff
- All changes to the appliance may be harmful.

- FOR OUTDOOR USE ONLY

The air needed for combustion is 2.0 m³/h for each kW of nominal capacity.

IF YOU SMELL GAS:

- Turn the burner off
- Close the appliance’s gas supply (cylinder tap)
- Call the gas supplier or a skilled person
- The support should not made of inflammable material and shall resist temperatures
of at least 90°C.

CONNECTION – REPLA

CONNECTION – REPLA

CONNECTION – REPLA

CONNECTION – REPLA

CONNECTION – REPLACEMENT OF GAS CYLINDER

CEMENT OF GAS CYLINDER

CEMENT OF GAS CYLINDER

CEMENT OF GAS CYLINDER

CEMENT OF GAS CYLINDER

Connection of the appliance to the cylinder shall be done by:

- BUTANE or PROPANE gas, minimum camping cylinder 3 Kg BUTANE
- Pressure retainer of 30 mbar BUTANE and PROPANE, with a capacity of 1.0 kg/h

minimum

- Flexible pipe in accordance with the regulations in force with a maximum length of

1.5 m

- Spray of foaming liquid to check gas leaks.

Summary of Contents for FO4P

Page 1: ...IPLE PURPOSE BURNERS WITH INTEGRATED SUPPORTS FOR OUTDOOR USE FO4P FO3P NOMINAL CAPACITY kW 7 25 g h 527 GAS G30 G31 30 mbar INJECTORS 140 CATEGORY I 3B P Read the instructions before using the appliance and keep them 105 4503 ...

Page 2: ...ance shall be performed by skilled staff All changes to the appliance may be harmful FOR OUTDOOR USE ONLY The air needed for combustion is 2 0 m h for each kW of nominal capacity IF YOU SMELL GAS Turn the burner off Close the appliance s gas supply cylinder tap Call the gas supplier or a skilled person The support should not made of inflammable material and shall resist temperatures of at least 90...

Page 3: ...ing band E The cylinder must be changed outdoors and far from heat sources Close cylinder with plug and place in an appropriate area F Use spray or foaming liquid to check there are no gas leaks TURNING BURNER ON TURNING BURNER ON TURNING BURNER ON TURNING BURNER ON TURNING BURNER ON FIG 1 Open cylinder by turning the tap counter clockwise Turn adjustment control left and bring flame close to the ...

Page 4: ...e cleaned with a damp sponge and detergent 3 Never leave salty liquids on the surface 4 ATTENTION never use abrasive detergents 5 To clean burners use a damp sponge and soap or a special detergent 6 If the burner is not used for a prolonged period of time replace in its package and keep in a dry and clean area 7 If the burner and Venturi holes are blocked never use metallic objects to unblock them...