10
ENGLISH
GB
8.2.
Installation (service technician)
All the stages of the installation must be carefully
planned.
The location should be equipped with all supply
connections and production waste outlet. The
location should also be properly lit and comply
with all hygiene and sanitary requirements
according to the binding regulations.
The device should be installed with the minimum
10 cm clearance from the wall.
Locate the device in the horizontal position by
adjusting the individual feet.
The device FTE91 must be fixed to the foot flange
at the bottom.
When the device is to be installed
near the walls, partitions, kitchen
cabinets, decorative elements, etc., they
must be made from non-flammable
materials or covered with suitable non-
flammable materials.
To ensure the correct operation
of the device, the device must be
installed
and
operated
in
the
thoroughly ventilated room only.
8.3.
Connection to the mains (service technician)
The device may be connected to the power supply
only by the authorized and qualified personnel,
when the valid regulations are followed and when
appropriate material is used in accordance to the
regulations.
Depending on the model the devices are designed
for connection to the following networks:
380-415 V 3N~ 50-60 Hz
During the installation follow the data on the rating
plate.
Before connecting the device to
the mains, check whether the device is
connected to the appropriate circuit
breaker in all poles with minimum air
gap of 3 mm.
To correctly connect the device, follow the
guidelines below.
Remove the cover from the terminal strip (A).
A
10 mm