6
ENGLISH
GB
4.6.
Exchange of components (service technician)
Before exchange of the
component switch on all the existing
protection devices.
First of all, switch off the gas valve and
prevent access to the appliance, which
in the case of activation may lead to
unexpected situations endangering the
safety and health of people.
If necessary, exchange the used components to
the original spare parts.
We are not liable for personal injury or
damage to the components that arise due to
application of other spare parts than original
or intervention into the device without the
manufacturer’s consent that may have altered
the safety requirements.
5.
USE AND OPERATION
5.1.
Description of the controls.
The elements controlling the essential functions
are located on the control panel of the device.
A) Gas control knob:
it regulates the gas
supply and changes the temperature.
B) Piezo igniter
: for igniting the ignition
flame of the burner.
5.2.
Burner ignition
ON
A)
In order to ignite the ignition flame, press the
knob of the selected gas burner and turn it left
(
position
1
). Light the ignition flame using a
match.
B)
Hold the gas control knob for ca. 10 seconds in
order to heat up the thermocouple, then release
the knob.
C)
To activate the gas burner, turn the gas control
knob left (
position 2
).
D)
Set the power of the gas burner (
position 3
).
Pos 1
Pos 2
Pos 0
P
Pos 3
Temperature
scale
A
B
Ignition Flame
symbol
Piezo igniter