- 37 -
•
The device belongs to the following design type:
A1: The device without fans or connection for devices removing the combustion
products from the rooms. The combustion air and combusted gases are
mixed in the same room.
•
Before positioning the device check the dimensions and exact positions of the
electric and gas connections.
•
Unpack the device and utilize all package material according to the valid regulations.
CAUTION!
Never remove the rating plate and any warning signs from the device.
•
Position the device in safe place of load capacity sufficient for weight of the device
with maximum load of prepared food.
•
Never place the device on a flammable surface or one sensitive to high temperatures.
•
Never place the device directly next to walls, furniture or other objects made of
flammable materials. Keep a minimum distance of 200 mm from the sides and rear.
Keep a minimum distance of 600 mm between the upper surface of the device and
surfaces located above it. Proceed according to relevant fire safety regulations.
•
If it is not possible to observe the above distances, apply protective measures
(e.g. heat-resistant coatings) that can resist temperatures of at least 90 °C .
•
Regulate the level and height of the device with the adjustable legs. Large differences
in height or level may have a negative impact on the device's functioning.
5.1.2 Electric connection
DANGER! Electric shock hazard!
The device can cause injuries due to improper installation!
Before installation and connecting the local power grid specification
should be compared with that of the device (see rating plate).
Connect the device only in case of compliance!
•
Before connecting the device make sure that the voltage and frequency values on
the rating plate are consistent with the existing electric installation.
The allowable voltage deviation is ±10%.