- 39 -
Operation in case of gas consistent with the device preset
Check if the gas type specified on the rating plate conforms to the supplied gas type.
Correct data are specified in Table 1 “Use of gas categories and pressures in
various countries” on page 34.
In case of no data for the supplied gas type, gas category, or pressure for
comparing with the rating plate contact the local gas supplier.
CAUTION!
The device operates correctly only when the pressure in the gas system is
in range for different gas categories specified in Table 1 “Use of gas
categories and pressures in various countries” on page 34.
Main burner control
•
Activate the device according to the instructions in section 5.2.3 “Ignition of gas
burners”, ignite the individual burners and see if the flame, ignition, and setting
of the smallest flame operate correctly. If not, check nozzles and setting of
primary air.
Changing the gas type / settings
CAUTION!
Change of gas type must be performed by the qualified gas installer.
•
The device is designed and certified for operation with
the gas type specified on the rating plate (natural gas).
•
When required, the device should be modified by the
qualified technician. In order to make modifications
replace the main burner nozzles (no. 2) and the ignition
burner (no. 1) and make required adjustments.
The delivery range includes nozzles for LPG.
1
2