Disposal
64 / 66
117650
EN
Alarm/
Message
Description
Situation
Solution
E14-
Hi temp
Too high a
temperature of
the switchboard
Thermal processing
interruption,
automatic operation
reactivation
Check cleanness of the
ventilation filter,
ventilation slots, and
correct operation of
cooling fans
E21-
No water
No water needed
for steam
generation
Thermal processing
interruption
Check water network
connection, make sure
that the water valve is
opened
E16-
Communi-
cation
PWM main
control board
communication
error
Thermal processing
interruption
Switching the voltage
off and on; if alarm
persists, contact the
service company
E22-
Electric
power supply
failure
Electric power
outage
Thermal processing
interruption
Check electric power
supply.
Keep the rotary control
knob 4 (Fig. 7) pressed
for 1 second
9
Disposal
Electrical Appliance
Electric appliances are marked with this symbol. Electrical
appliances must be disposed of and recycled in a correct
and environmentally friendly manner. You must not dispose
of electric appliances with household waste. Disconnect the
appliance from the power supply and remove power cord
from the appliance.
Electrical appliances should be returned to designated collection points.