Configuration through web interface
–
15
Photoresistor setting: Range of sensitivity level of the photoresistor at night and day (0-100) for
switching the mechanical IR filter of the camera. The default values are 5 - 37.
The left value in this menu is the threshold at which the panel will switch to the “night” mode
and will display the image in black and white. The right value in this menu is the threshold at
which the panel will go into normal mode and will display a color image.
These values are set based on the lighting parameters and the degree of illumination of the
object where this panel is installed.
Tamper alarm: Enable/disable alarm triggering function by tamper (accelerometer) activation.
Gravity sensor thersold: Level of operation of an accelerometer (0 - 127).
The default value is 32. When the minimum value is set, the panel will make a siren sound when
it is removed from the seat and moved from the vertical to the horizontal position. When you set
the maximum value, the panel will emit a siren sound with a strong vibration or even hit it.
Location settings: Building, unit, floor, apartment number, sequence number, synchronization
code.
Server IP: The IP address of the server with the Management Software.
Wiegand
Wiegand Type: The type of Wiegand interface used. Wiegand-26 and Weigand-34 support is
available.
Blinking time: The flashing frequency of the call button LEDs when the lock is opened (500 ms -
5000 ms).
Relay
Select “Relay” to access the configuration of the relay outputs:
In this field it is necessary to enter the same values of the logical address as on the
monitor, from which this panel will be viewed later.