Troubleshooting

12

Pump Alarm- E4 Error Code

**

UNIT WILL NOT FUNCTION UNTIL ERROR CODE IS CLEARED.

If E4 (pump alarm) is shown on the display, complete the following steps:

1. Reset the unit by unplugging the power cord and then reconnecting it.

2. Manually check to see if the pump is operational by pressing the drain button. Check 

if the pump energizes and de-energizes properly. Additionally, check to see if any water 

purged from the system.

3. If you haven’t cleaned the system recently, check the discharge line for an obstruction, 

then clean as described in the Maintenance section.

4. Replace the hose and/or pump, if maintenance alone isn’t sufficient. 

Solution

Cause

Symptom

Poor Connection

Verify that both ends of the power cord are 
plugged in

Power Outage

Reset power

Trouble Code: 

LO

Clean the filter 

Clear the blockage

 

Filter is Dirty

Air Inlet or Outlet is Blocked.

Diaplay is Blank

No AirFlow

Trouble Code: 

E4

Trouble Code:  

E1

Problem with Pump

Room Temperature is 
below 33.8

Humidity Sensor or 
Communication Error

Check to ensure that the sensor wire is 
connected at both ends, if no issues are 
visible, the sensor may be faulty.

Verify that the pump is properly installed 
and functioning. If so, unplug the unit for 
two minutes, then restart.

Increase the room temperature so it is 
within operation range (above 33.8

). If 

error still display, check sensor.

Trouble Code: 

HI

Room Temperature is 
above 

104℉

Decrease the room temperature so it is 
within operating range (below 

104℉

). If 

error still displays, check the sensor.

E5

 Trouble Code

Refrigerant Leak

Contact Your Installer for Assistance.

Summary of Contents for AirWerx 100X

Page 1: ...Tel 1 888 641 8862 Web www baseaire com E mail sales baseaire com Installation Operations Manual AirWerx 100X Patent pending Specifications subject to change without notice...

Page 2: ......

Page 3: ...it Works Installation Requirements Installation Key Functions Indicator Lights Remote Control Operating Instructions Unit Diagram Maintenance Dehumidifier Storage Ducted Applications Troubleshooting...

Page 4: ...ant Notes Always connect your dehumidifier using a grounded electrical connection as required for all electrical appliances The use of non grounded wiring will void the warranty Your dehumidifier shou...

Page 5: ...ither the inlet or discharge should be positioned against a wall The inlet needs a minimum of 12 clearance and the discharge requires a minimum of 36 clearance For the best air diffusion install the u...

Page 6: ...n mind that the displayed humidity levels are approximate 5 3 Continuous Mode To set the unit to run continuously regardless of humidity simply use the down arrow key to set the humidity below 35 1 Pl...

Page 7: ...it is in auto defrost mode and clearing the evaporator coils of any ice buildup 4 Compressor Light When the light illuminates red it indicates the compressor has been initiated but is currently warmin...

Page 8: ...n Press the on off button and the machine will start running two beeps Press the button again to turn the machine off 2 Up Button Down Button Use the up and down arrows to adjust the humidity level 3...

Page 9: ...ss the power button again and the dehumidifier will stop Note that the fan will continue to operate for 1 minute after the unit has shut off The AirWerx 100X has an integrated condensate pump During n...

Page 10: ...8 Unit Diagram Front View Back View Control Panel Handle Side Panel Pre filter Discharge Grille Power Cord Ventilation Fan Port Optional Remote Control Drain Hose Connection Auxiliary Terminals...

Page 11: ...n The pump requires routine maintenance that is not covered by the warranty Preventative maintenance is necessary to prevent issues from dirt and slime that may accumulate in the drain system This inc...

Page 12: ...rvoir a wet dry vacuum or towels can be used to remove any remaining water 2 Unplug the dehumidifier and remove the cover so you have access to the pump 3 Remove the pump head from the reservoir by un...

Page 13: ...ting the dehumidifier allows the unit to be in one room while conditioning an adjacent room Both the inlet return grille and the supply grille are designed for 10 flex ducting Ducting Installation Not...

Page 14: ...fy that both ends of the power cord are plugged in Power Outage Reset power Trouble Code LO Clean the filter Clear the blockage Filter is Dirty Air Inlet or Outlet is Blocked Diaplay is Blank No AirFl...

Page 15: ...x Main Control Board AirWerx Display Board AirWerx RH Temp Sensor Internal Components Compressor Compressor Capacitor Coil Assembly Hot Gas Valve Assembly Condensate Pump Assembly Filters External Com...

Page 16: ...er is responsible for all risk of loss or damage BaseAire Warranty Steps 1 Once receive the goods customers must log in www baseaire com to fill out the warranty Registration form and submit to BaseAi...

Page 17: ...ANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE BaseAire...

Page 18: ......

Page 19: ......

Page 20: ...Scan QR Code to Register Warranty...

Reviews: