Capacity @ 80°F/60%RH:
100 Pints Per Day
Airflow @ 0.0” SP:
250CFM
Operating Temp. Range:
33.8-104°F
Operating Relative Humidity Range:
35%-90%
COP:
2.7 L/kWh
Refrigerant:
R410A
Amperage Usage:
6.82 Amps
Power Supply:
115V/60Hz/Single Phase
Outlet Requirement:
15 Amp
Sound Level:
60 dBa
Dimensions LxWxH:
23.8” x 14.7” x 17.9”
ETL Listed:
Yes
3
Specifications
How It Works
Installation Requirements
• The area where the dehumidifier is located should be sealed with a vapor barrier.
• If the unit is installed in a crawl space, all vents should be sealed.
• For proper ventilation, neither the inlet or discharge should be positioned against a wall.
The inlet needs a minimum of 12” clearance and the discharge requires a minimum of 36”
clearance.
• For the best air diffusion, install the unit so that a side panel faces the wall.
• AirWerx dehumidifiers are only intended for operation when the unit is upright and level
with the feet on the ground.
AirWerx dehumidifiers use an integrated humidistat to monitor theconditioned space. When
the relative humidity goes above the selected setpoint, the dehumidifier will energize. Air is
then drawn across an evaporator coil, which is cooler than the dew point of air. This means
moisture will condense out of the air. The air is then reheated through the condenser coil and
distributed back into the room.