Figure 6:
Level bubble
should be in indicator
area for proper
drainage.
6.3 CondensaTe (WaTer) reMoVal:
The unit drains via a
gravity system - it is not able to push condensate (water) uphill.
The drain hose must run flat or downhill toward the drain location.
Be sure the hose is not kinked or otherwise restricted so that
water can pass through it. Improper hose installation may result in
water leakage.
To increase the efficiency of the unit, position the hose to create a
“trap” as shown in Figure 8. By creating a trap, it will hold a small
amount of water. Position the trap on the hose approximately 12”
to 20” away from the unit. Check hose regularly to ensure it is
clear and water is draining properly.
If a floor drain is not easily accessible, a condensate pump kit
with a 20’ hose is available. Refer to 6.4 Condensate pump
installation.
6.4 CondensaTe PuMP insTallaTion (oPTional)
In the
event that a gravity drain directly from the unit is not available, a
separate condensate pump is needed. In order to use a separate
condensate pump, the SaniDry CX will need to be raised up on
blocks in order to maintain the gravity feed out of the SaniDry CX
and into the condensate pump for proper condensate removal.
1. Position SaniDry CX onto blocks to raise unit to maintain gravity
feed of condensate discharge from unit. Ref. 6.2 drain hose.
2. Position the condensate pump so the discharge line from
the unit can be shortened and placed into the condensate
pump. Measure the distance from the drain port to the
condensate pump leaving enough length to install the hose into
the condensate pump.
3. Cut the provided ¾“ discharge hose long enough to reach the
condensate pump. Cut ¾” hose end at a 45-degree angle on
one end.
4. Place cut end into condensate pump.
5. Run discharge line from condensate pump to the
discharge area.
SaniDry CX INSTALLER'S AND OWNER'S MANUAL
4
SaniDry CX Installer’s & Owner’s Manual
Figure 8:
Optimum hose position for draining
Figure 7:
Drain hose position
Condensate Pump Kit
STEP 1
STEP 4
STEP 2
STEP 5
STEP 3
sanidry CX Condensate Pump installation instructions