7. oPeraTion

7.1 Fan Control 

“UNIT OFF” means no power is supplied to 

the unit. It will not operate.

“Fan runs all the time to circulate air”

 means fan runs always, 

compressor runs only as required to maintain humidity set point. 
This function is desirable if the unit is used for air circulation or 
filtration.

“Fan only runs when dehumidifier is on”

 (Recommended 

setting) means the fan and compressor run together as required 
to maintain humidity set point. Once humidity set point is reached 
the whole unit will shut off until the relative humidity rises and 
further dehumidification is needed.

7.2 Humidity Control adjustment

 The humidity control 

allows the humidity setting to be adjusted to obtain the required 
humidity level. The humidity control tells the dehumidifier when 
to dehumidify. Dehumidification will take place when the relative 
humidity (RH) of the air in which the dehumidifier is located rises 
5% RH above the dial set point. Dehumidification will stop when 
the RH drops 5% below the set point.

approximate Humidity levels Per setting
“drier”

 35% to 45% Relative Humidity

“normal”

 45% to 55% Relative Humidity(Recommended for most 

applications)

“Humid”

 55% to 65% Relative Humidity

The dehumidifier will run continuously until the relative humidity 
(RH) is reduced to the humidity control dial setting. There is 
no benefit to setting the humidity control to “drier” in rooms 
under 65°F; doing so will result in long periods of ineffective 
dehumidifier run time.
Once the dial has been set to the desired level of humidity control, 
the unit will maintain the same percentage of relative humidity 
regardless of room temperature within 3-5% RH.
To turn the unit off, you can set the “Fan Control” to “UNIT OFF”, 
or you can position the humidity control to the far left and set fan 
control to “Fan only runs when dehumidifier is on”.

 

CAUTION!

 

When the compressor stops running for any reason it will not 
restart for 3 minutes. When it starts, it will run for a minimum 
of 5 minutes regardless of the % rH setting.

8 deFrosT CyCle

An automatic defrost temperature sensor is attached to the 
refrigerant tubes inside the unit. It will automatically shut the 
compressor off if excessive frost forms on the evaporator coil. 
The blower will continue to run, causing air to flow through the 
evaporator coil and melt the ice. When the ice has melted, the 
evaporator temperature will rise and the defrost temperature 
sensor will automatically restart the compressor. During the 
defrost cycle process, the compressor will not be running and cool 
air may be coming out of the unit.

9. MainTenanCe

 

CAUTION!

 

noTe: do not operate the unit without the proper filter or 
with a less effective filter. The heat exchange coils inside the 
unit could become clogged, resulting in premature failure 
of refrigeration components, a loss of effectiveness and/or 
efficiency, which may require total disassembly to clean.

9.1 air Filter 

The SaniDry CX ships with a standard MERV-11 

65% 1” pleated fabric filter and a 1/4” aluminum framed pre-filter 
installed. Operating the unit with a dirty or obstructed filter will 
reduce dehumidifier capacity and efficiency and may cause the 
compressor to cycle on and off unnecessarily.

9.2 Filter Cleaning & replaCement 

Check filters every 

six months or more frequently depending on room conditions. 
Clean and/or replace when filters are visibly dirty. See cleaning 
instructions below. For replacement filters, call your local 
Basement Systems dealer. 

Figure 11:

 Pre-filter 

rinsed in Water, mesh 
side up

The 1/4” washable 
pre-filter should not be 
discarded.
Inspect the pre-filter for 

debris, dirt, or other obstructions at the same time the 1” pleated 
fabric filter is checked. Wash the 1/4” pre-filter every time the 
1” pleated fabric filter is replaced. To clean the 1/4” pre-filter, 
remove filter from the unit, ref. section 9.3, rinse the 1/4”pre-
filter in water with the water flowing through the aluminum 
support mesh side. Refer to Figure 11. Allow the pre-filter to 
dry completely before reinstalling. Reinstall the filters per the 
instructions in section 9.4 Installing Filters. 

 

CAUTION!

 

noTe: Failure to follow filter installation instructions may 
result in improper function of the dehumidifier and cause 
premature component failure.

SaniDry CX INSTALLER'S AND OWNER'S MANUAL

5

SaniDry CX Installer’s & Owner’s Manual

Figure 9:

 dial shown in recommended position

Summary of Contents for CX-109

Page 1: ...nstallation operating and safety instructions warranty information n Read and save these instructions www BasementSystems com For product information go to www SaniDryDehumidifier com By INSTALLER S O...

Page 2: ...ctions is essential to obtaining maximum efficiency from your dehumidifier Read and Save These Instructions WARNING This symbol means important instructions Failure to heed them can result in serious...

Page 3: ...t hand side of unit high enough to thread remaining two feet into bottom of base approximately 10 revolutions 3 Level unit for proper drainage as described in section 6 3 Figure 6 of this manual Figur...

Page 4: ...not available a separate condensate pump is needed In order to use a separate condensate pump the SaniDry CX will need to be raised up on blocks in order to maintain the gravity feed out of the SaniD...

Page 5: ...refrigerant tubes inside the unit It will automatically shut the compressor off if excessive frost forms on the evaporator coil The blower will continue to run causing air to flow through the evaporat...

Page 6: ...ervice people should service this unit For Service call your local Basement Systems dealer 11 Technical Description The SaniDry CX uses a refrigeration system similar to an air conditioner s to remove...

Page 7: ...ove has fixed the issue call the service department at 1 800 640 1500 Replacement Parts For more information on the SaniDry CX call 1 800 640 1500 Accessory Name QTY PC Specifications Material 1 Pre f...

Page 8: ...Exploded View SaniDry CX SERVICE PARTS LIST To order contact your local Basement Systems Dealer 8 SaniDry CX Installer s Owner s Manual...

Page 9: ...Make sure the Exhaust Duct Ring is seated all the way down in slots 2 Connect the flexible duct hose to the Exhaust Duct Ring 3 Position grille and sheet metal duct flange accordingly to exhaust to p...

Page 10: ...nty claim to BSI such that BSI receives such claim prior to the end of the applicable warranty period BSI shall have no obligation hereunder with respect to any claim received by BSI after the expirat...

Reviews: