controller to excessively low levels in cool rooms. Doing so will 
result in long periods of ineffective dehumidifier run time. An ideal 
setting is 55%, which prevents mold growth.

3.2  on/off:

 Pressing the ON/OFF button once will power up the 

control system and illuminate the RED RUN LED.  The unit will 
now operate in either AUTO DEHUMIDIFY or FAN MODE.  Pressing 
the ON/OFF button again will return the unit to STANDBY MODE.  
The RED RUN LED will flash.

3.3  MoDe:

 Use the MODE button to select AUTO DEHUMIDIFY or 

FAN mode of operation.

3.4  UP/DoWn aRRoWS:

 Pressing the UP/DOWN arrow buttons 

will display and change the desired %RH.  The selectable %RH 
range is 26 - 90%.  These buttons will function while in either the 
AUTO DEHUMIDIFY or FAN MODE.

3.5 

 

BUTTon PReSSinG Tone: 

Pressing any function button will 

sound a tone.

4. leD DiSPlaY

4.1  RUn leD:

 This RED indicator will flash when in STANDBY 

MODE.  It will remain illuminated while in either AUTO DEHUMIDFY 
or FAN MODE.

4.2  DefRoST leD:

 This RED indicator will be illuminated while 

in the DEFROST MODE, otherwise it will be extinguished.

4.3  aUTo DeHUMiDifY leD:

 This GREEN indicator will be 

illuminated while in the AUTO DEHUMIDIFY MODE, otherwise it will 
be extinguished.

4.4  fan leD:

 This GREEN indicator will be illuminated while in 

the FAN MODE, otherwise it will be extinguished.

5. DiGiTal DiSPlaY

5.1 DiGiTal DiSPlaY RelaTiVe HUMiDiTY %: 

The digital 

display will show the current %RH. in the room that the 
dehumidifier is located while in stand by mode or while running in 
AUTO DEHUMIDFY or FAN MODES.

5.2

 

DiGiTal DiSPlaY RelaTiVe HUMiDiTY % SeT PoinT: 

The digital display will show the % RH set point when a new 
setting is selected using the UP/DOWN arrow buttons.

5.3 DiSPlaY CoDeS:

 E1 indicates that the coil temperature 

sensor is not functioning properly.
E2 indicates that the humidity sensor is not functioning properly.
CO indicates that the unit is running in continuous dehumidify 
mode.

6. MeMoRY/PoWeR failURe

If a power failure occurs, the unit will store the last selected 
mode of operation and %RH settings for up to one year.  When 
power returns, the SaniDry XP will resume operation in the mode 
previously selected.

7. oPeRaTinG MoDeS:

7.1 PoWeR UP

: When the unit is powered up, it will be in 

STANDBY MODE indicated by the flashing RED RUN LED. All other 
LEDs are extinguished.  None of the buttons are functional except 
ON/OFF.  The compressor and fan will not run. 

7.2 DefaUlT SeTTinGS afTeR PoWeR UP:

 The control unit 

displays the current %RH humidity condition of the room and sets 
the %RH goal to 60%.

7.3 aUTo DeHUMiDifY MoDe:

  When AUTO DEHUMIDIFY MODE 

is selected, the GREEN DEHUMIDIFY and RUN RED LED will be lit 
and the digital display will show the current %RH of the room.  
The %RH set range is 26- 90%.  When the set point is lower than 
the current %RH of the room, the compressor and fan will run.  
When the current %RH of the room is equal to or less than the set 
point, the compressor will stop.  The fan will continue to run for 
an additional 30 seconds.  When the set point is less than 26%, 
the digital display will show CO.  This indicates that the unit will 
dehumidify continuously.

7.4 CHanGinG MoDeS:

 Press the MODE button to change the 

operating mode from AUTO DEHUMIDIFY to FAN or back to AUTO 
DEHUMIDIFY.  The corresponding LED will be lit to indicate the 
current operating mode.

7.5 fan MoDe:

 When the FAN MODE is selected, the fan will 

run continuously, the GREEN FAN and RED RUN LED'S will be lit, 
the digital display will show the current %RH of the room. The 
%RH set range is 26- 90%.  When the set point is lower than the 
current %RH of the room, the compressor will run.  When the 
current %RH of the room is equal to or less than the set point, the 
compressor will stop but the fan will continue to run.

7.6 STanDBY MoDe

: The unit will return to STANDBY MODE 

each time the ON/OFF button is pressed to leave the FAN or AUTO 
DEHUMIDIFY MODES indicated by the flashing RUN RED LED.  
When running in FAN OR AUTO DEHUMIDIFY MODE and the %RH 
set point is satisfied, the compressor will shut off, the fan will run 
for an additional 30 seconds and the defrost timer will be reset.  If 
the ON/OFF button is pressed before the fan shuts off and the unit 
returns to STANDBY MODE, the compressor will not start when the 
RUN button is pressed until the this timer has run out.  The control 
unit does not monitor sensor information while in STANDBY 
MODE.

SaniDry XP INSTALLER'S AND OWNER'S MANUAL

4

SaniDry XP Installer’s & Owner’s Manual

Summary of Contents for SD109 SaniDry XP

Page 1: ......

Page 2: ...the Sensors 5 8 8A Coil Sensor 5 8 8B Humidity Sensor 5 9 Other Functions 5 9 1 Control Lock 5 9 2 Display Coil Temperature 5 10 Electromagnetic Compatible Standard 5 10 1 EMS Criteria 5 10 2 EMC Crit...

Page 3: ...om Pressurization assures that open combustion devices do not backdraft This can be accomplished by installing a duct from the humid room to the SaniDry XP inlet and by allowing the SaniDry XP to disc...

Page 4: ...in the mode previously selected 7 OPERATING MODES 7 1 POWER UP When the unit is powered up it will be in STANDBY MODE indicated by the flashing RED RUN LED All other LEDs are extinguished None of the...

Page 5: ...DEFROST CYCLE every 53 minutes of operation 8 8B HUMIDITY SENSOR When the humidity sensor s output voltage is less than 0 5V or more than 4V the control unit considers it faulty and will display E2 i...

Page 6: ...efrigerant liquid then passes through a filter drier and capillary tubing which cause the refrigerant pressure and temperature to drop It next enters the evaporator coil where it absorbs heat from the...

Page 7: ...porator 1 SS 0 6mm 31 Tubing evaporator 1 9 52mm OD x 8mm wall copper tubing 32 Grommet 1 Buna N 33 Capillary 2 2 5mm OD x 1 0mm wall 34 Tubing discharge 1 6 35mm OD x 8mm wall copper tubing 35 Filter...

Page 8: ...SaniDry XP SERVICE PARTS LIST To order contact your local Basement Systems Dealer 8 SaniDry XP Installer s Owner s Manual Exploded View...

Page 9: ...edrilled mounting holes are located near the bottom and on the same side of the unit as the drain hose STEP 5 Example of hose cut at a 45 angle The angle prevents the hose from sealing tight against t...

Page 10: ...x and bend the tabs in 6 Place the collar over the blower outlet and line up the tabs with the holes in the cabinet 7 Using 4 screws from the kit attach the collar to the unit collar Ductable Inlet Ex...

Page 11: ...nty claim to BSI such that BSI receives such claim prior to the end of the applicable warranty period BSI shall have no obligation hereunder with respect to any claim received by BSI after the expirat...

Reviews: