SaniDry XP SERVICE PARTS LIST

 

 

To order, contact your local Basement Systems Dealer

NO 

DESCRIPTION 

QTY 

SPECIFICATIONS

Wheel 

Plate, Bottom 

Galvanized steel (1.5mm)

Bracket 

Galvanized steel (1.0mm)

Grommet, rubber – compressor 

Buna N

Washer, plate 

6mm dia. Steel

Nut 

M6 steel

Capacitor, compressor 

35µF/250V

Compressor 

5RS080UAA21 115VAC/60HZ  R410A

Gasket, cover – terminal 

EPT

10 

Spring, hold down 

SS

11 

Overload protector 

B290-150-241H

12 

Cover, terminal 

PET

13 

Gasket, nut 

5mm dia  PET

14 

Cover, terminal – nut 

M5 steel

15 

Seal, lower - condenser 

PU

16 

Seal, side – condenser 

PU

17 

Condenser 

18 

Seal, upper – condenser 

PU

19 

Trough, collection - water 

SS

20 

Probe, temperature 

21 

Evaporator 

22 

Seal, heat exchanger - vertical 

PU

23 

Seal, heat exchanger - horizontal 

PU

24 

Probe, humidity 

25 

Cover, probe - humidity 

ABS

26 

Heat exchanger 

PP

27 

Guide, filter 

SS (0.6mm)

28 

Seal, guide 

PU

29 

Cabinet 

Powder-coated steel (1.0mm)

30 

Bracket, evaporator 

SS (0.6mm)

31 

Tubing, evaporator 

9.52mm OD x .8mm wall copper tubing

32 

Grommet 

Buna N

33 

Capillary 

2.5mm OD x 1.0mm wall

34 

Tubing, discharge 

6.35mm OD x .8mm wall copper tubing

35 

Filter 

36 

Tubing, process 

6.35mm OD x .8mm wall copper tubing

37 

Tubing, condenser 

9.52mm OD x .8mm wall copper tubing

38 

Insulation 

PE

39 

Tubing, suction 

9.52mm OD x .8mm wall copper tubing

40 

Line cord 

3 wire 16AWG/125V/13A/105˚C/300V

41 

Cordgrip 

ABS

42 

Grommet 

Buna N

43 

Screen, fan 

Steel

44 

Control unit 

115V/60Hz

45 

Insulation, trough – water collection 

PE

46 

Damper, mass 

47 

Housing, fan 

Powder-coated steel (1.0mm)

48 

Motor, fan 

115V/60Hz

49 

Washer, motor - fan 

Silicon Rubber 97mm OD x 7mm thick 

50 

Capacitor, fan 

12.5µF/250V

51 

Isolator, vibration - fan 

PE

52 

Rotor, fan 

Aluminum

53 

Deflector, air 

Powder-coated steel (1.0mm)

54 

Wire 

16-20AWG/105˚C/600V/VW-1

55 

Clamp, tubing 

SS

56 

Tubing, drain 

16mm ID x 1.8m PVC

57 

Cover, cabinet 

Powder-coated steel (1.0mm)

58 

Insulation, cover - cabinet 

PE

59 

Insulation, cabinet - lower 

PE

60 

Insulation, cabinet - upper 

PE

61 

Filter, pleated – paper 

62 

Filter, aluminum 

7

SaniDry XP Installer’s & Owner’s Manual

Summary of Contents for SD109 SaniDry XP

Page 1: ......

Page 2: ...the Sensors 5 8 8A Coil Sensor 5 8 8B Humidity Sensor 5 9 Other Functions 5 9 1 Control Lock 5 9 2 Display Coil Temperature 5 10 Electromagnetic Compatible Standard 5 10 1 EMS Criteria 5 10 2 EMC Crit...

Page 3: ...om Pressurization assures that open combustion devices do not backdraft This can be accomplished by installing a duct from the humid room to the SaniDry XP inlet and by allowing the SaniDry XP to disc...

Page 4: ...in the mode previously selected 7 OPERATING MODES 7 1 POWER UP When the unit is powered up it will be in STANDBY MODE indicated by the flashing RED RUN LED All other LEDs are extinguished None of the...

Page 5: ...DEFROST CYCLE every 53 minutes of operation 8 8B HUMIDITY SENSOR When the humidity sensor s output voltage is less than 0 5V or more than 4V the control unit considers it faulty and will display E2 i...

Page 6: ...efrigerant liquid then passes through a filter drier and capillary tubing which cause the refrigerant pressure and temperature to drop It next enters the evaporator coil where it absorbs heat from the...

Page 7: ...porator 1 SS 0 6mm 31 Tubing evaporator 1 9 52mm OD x 8mm wall copper tubing 32 Grommet 1 Buna N 33 Capillary 2 2 5mm OD x 1 0mm wall 34 Tubing discharge 1 6 35mm OD x 8mm wall copper tubing 35 Filter...

Page 8: ...SaniDry XP SERVICE PARTS LIST To order contact your local Basement Systems Dealer 8 SaniDry XP Installer s Owner s Manual Exploded View...

Page 9: ...edrilled mounting holes are located near the bottom and on the same side of the unit as the drain hose STEP 5 Example of hose cut at a 45 angle The angle prevents the hose from sealing tight against t...

Page 10: ...x and bend the tabs in 6 Place the collar over the blower outlet and line up the tabs with the holes in the cabinet 7 Using 4 screws from the kit attach the collar to the unit collar Ductable Inlet Ex...

Page 11: ...nty claim to BSI such that BSI receives such claim prior to the end of the applicable warranty period BSI shall have no obligation hereunder with respect to any claim received by BSI after the expirat...

Reviews: