54
When the device is in the holiday mode, the set temperature is
maintained while in this mode. Program settings are only obtained
when the countdown of the holiday mode is at 0 or the Holiday
Mode is reset to 0!
Heat/Cool control
The device can be used to control a heater or a cooler. In heating mode, the ther-
mostat switches the connected device off when the target temperature is exceeded.
In cooling mode, the thermostat switches the connected device on when the
target temperature underrun.
The operating mode is indicated with the flame symbol (9: heating mode) and
the snowflake symbol (10: cooling mode).
Also a delay of 5 minutes can also be set. This is used as switching hysteresis in
order to protect the connected devices from too frequent switching.
To make the setting, go to the function settings as described under Holiday
mode. Use the buttons “ “ and “ “ to select “Ht“ for the heating or “CL“ for
the cooling system. Press “OK” to confirm.
To enable the delay, press and hold the „SET“ button for 3 seconds.
Use “SELECT” to change from the time setting “ti” to the function setting “St”
and confirm with “SET”.