background image

b) Power supply requirements

The power supply voltage needs to be stabilized and there must be no

high frequency noise (ripple voltage) since this could significantly reduce

the obtained reading range.

c) Data format on the Wiegand 42 interface

On the Wiegand 42 interface a sequence of 42 pulses (bits) is transmitted on the ‘WG0’ and ‘WG1’ lines
Both output signals are open collector type. The connected access control terminal will pull up the lines to 

+5-12V level in quiet state.
For a complete ID-code transmission 42 negative pulses with a duration of 100Gs each and delay of 2 mS 

between consecutive pulses are sent. 
Depending a logic ‘0’ or ‘1’ the pulses are transmitted on the ‘WG0’ or ‘WG1’ line.
The ID-code of the transponder is 40Bit and two parity bits are added for validation of the transmission. The 

transmission starts with an added ‘even’ parity bit for the first 20 data bits and ends with added ‘odd’ parity 

bit calculated from the later 20 data bits.
 

E (b0  . . . . . . . . . . . . . . . .  b19)  

(b20  . . . . . . . . . . . . . . . .  b39) O

Example:
 

1  0101  1101  0001  1010  0010  

0001  0100  0110  0011  1100  1

The parity bits are calculated for the first 21 bits of the transmission always having a even number of ones 

while the last 21 bits will always have an odd number of ones.

d) Data format on the RS-485 interface

The data output on the RS-485 interface will start immediately after the transmission on the Wiegand 

interface is completed.
The 40 bit of the ID-code are send as 5 consecutive bytes without any additional packet framing, header or 

checksum added.
The transmission speed is 9600 bps (104GS per bit). The transmission  uses 8 data bits, one start bit and 

one stop bit (8N1).

Mounting instructions

The RFID reader can be mounted to an even surface using the 4 holes in the corners.
The antenna must be installed on a non-metallic surface since metal objects will degrade the reading 

performance of the Antenna significantly.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in the household waste. 

At the end of its service life, dispose of the product in accordance with applicable regulatory 

guidelines.

 

You thus fulfill your statutory obligations and contribute to the protection of the environment.

Technical Data

Dimensions ........................................... 240 x 240 x 35 mm
Connection cable ..................................

fixed, 6 pin, 2 m

Input power ........................................... 12 – 15 V/DC / max. 200 mA
Transponder reading range .................. Max. 80 cm
Interfaces .............................................. Wiegand 42 / RS - 485 9600 / 8N1
Allowed temp. ....................................... 0 to +40 °C (non-condensing)
Operating frequency ............................. 125 kHz
Compatible RFID transponders ............ EM410x comp. 64 / 40 Bit ROM
Transmission power.............................. < 10 mW ERP (as req. CE / RED )

Compatible accessories .......................  B/N 1839710 Transponder card 

 B/N 1839711 Key chain transponder 

 B/N 1840879 Power supply module 

 B/N 1839715 Access controller for 400 users

 Operating Instructions

Long Range RFID Reader

Item No. 1839714

Intended use

The Long Range RFID Reader operating on 125kHz is designed to read the ID information from RFID tags 

and transmit this data to a connected access control system. 
The unit is equipped with two data interfaces:
•  Wiegand 42-Bit interface
•  RS-485 serial interface operating with 9600bps / 8N1

Contact with moisture must be avoided under all circumstances.

For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product 

for purposes other than those described above, the product may be damaged. In addition, improper use 

can result in short circuits, fires, electric shocks or other hazards. Read the instructions carefully and store 

them in a safe place. Make this product available to third parties only together with its operating instructions.
This product complies with the statutory national and European requirements.
All company names and product names are trademarks of their respective owners. All rights reserved.

Delivery Content

1 x long range antenna with 2 meter connection cable
4 x screws for mounting to wall

Up-to-date Operating Instructions           

Download the latest operating instructions at www.conrad.com/downloads or scan the 

QR code shown. Follow the instructions on the website.

Explanation of symbols

 

The symbol with the lightning in the triangle is used if there is a risk to your health, e.g. due to an 

electric shock.

 

The symbol with the exclamation mark in the triangle is used to indicate important information in 

these operating instructions. Always read this information carefully.

Safety instructions

Read the operating instructions carefully and especially observe the safety information. 

If you do not follow the safety instructions and information on proper handling in this 

manual, we assume no liability for any resulting personal injury or damage to property. 

Such cases will invalidate the warranty/guarantee.

•  The handling of products operating with electric current requires you to follow the rules from 

VDE such as VDE 0100, VDE0550/0551, VDE 0700, VDE 0711 and VDE 0860 or other local 

rules in your country.

•  These modules are not designed and authorized for use in life support or life saving 

applications! Do not use the product for applications in which a temporary or permanent failure 

or malfunction could cause damage to persons or property.

•  If the module is used to switch currents greater 24V it is necessary to have the installation 

done with no voltage applied and performed by a trained professional authorized for such 

work. The module may only be used in such application if it was installed in a safe to touch 

enclosure.

•  The module must only be used in dry and clean environment. The use near water, heavy dirt 

and/or high humidity is dangerous and not permitted.

• 

The product must not be used in conjunction with any type of flammable liquid or gas or other 

environment with risk of spark triggered explosions.

•  Never exceed the limits or ratings listed in the ‘Technical Data’ section at the end of this user 

guide.

•  If the module is used in schools or educational facilities or similar institutions the operation 

must be supervised by trained and authorized staff.

•  The product itself and all parts thereof (including packing material) are not suitable toys for 

children! (choking hazard, risk of electric shock, ...)

Operation

a) Connection wire assignment

The 6-wire interface cable uses this color coding for the signals:

red

power 12-15V DC

black

power supply 0V (Data - GND)

green

Wiegand42 Interface ‘WG0’

white

Wiegand42 Interface ‘WG1’

blue

RS-485 Interface ‘A’

yellow

RS-485 Interface ‘B’

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights 

including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication 

represent the technical status at the time of printing.
Copyright 2018 by Conrad Electronic SE. 

 

  

*1839714_v1_1018_02_dh_m_en

Summary of Contents for BT-1839714

Page 1: ...Lesen Sie sich die Bedienungsanleitung genau durch und bewahren Sie diese auf Reichen Sie das Produkt nur zusammen mit der Bedienungsanleitung an dritte Personen weiter Dieses Produkt erfüllt die gesetzlichen nationalen und europäischen Anforderungen Alle enthaltenen Firmennamen und Produktbezeichnungen sind Warenzeichen der jeweiligen Inhaber Alle Rechte vorbehalten Lieferumfang 1 x Long Range An...

Page 2: ...ition improper use can result in short circuits fires electric shocks or other hazards Read the instructions carefully and store them in a safe place Make this product available to third parties only together with its operating instructions This product complies with the statutory national and European requirements All company names and product names are trademarks of their respective owners All r...

Page 3: ...iegand de 42 bits Interface sérielle RS 485 de 9600 bps 8N1 Tout contact avec l humidité doit être évité en toutes circonstances Pour des raisons de sécurité et d homologation toute restructuration et ou modification du produit est interdite Le produit pourrait être endommagé en cas d utilisation autre que celle décrite ci dessus De plus une mauvaise utilisation pourrait entraîner des risques tels...

Page 4: ... of andere gevaren Lees de gebruiksaanwijzing aandachtig door en bewaar deze op een veilige plaats Het product mag alleen samen met de gebruiksaanwijzing aan derden worden overhandigd Het product is in overeenstemming met de nationale en Europese wettelijke voorschriften Alle bedrijfs en productnamen zijn handelsmerken van de betreffende eigenaren Alle rechten voorbehouden Leveringsomvang 1 x lang...

Reviews: