DAB:
,
,
(+30)
b
I
a
I
a
I
ˆ
ˆ
'
ˆ
c
I
b
I
b
I
ˆ
ˆ
'
ˆ
a
I
c
I
c
I
ˆ
ˆ
'
ˆ
DAC:
,
,
(-30)
c
I
a
I
a
I
ˆ
ˆ
'
ˆ
a
I
b
I
b
I
ˆ
ˆ
'
ˆ
b
I
c
I
c
I
ˆ
ˆ
'
ˆ
REV:
(+180)
a
I
a
I
ˆ
'
ˆ
b
I
b
I
ˆ
'
ˆ
c
I
c
I
ˆ
'
ˆ
R1:
,
,
(+120)
c
I
a
I
ˆ
'
ˆ
a
I
b
I
ˆ
'
ˆ
b
I
c
I
ˆ
'
ˆ
R2:
,
,
(+240)
b
I
a
I
ˆ
'
ˆ
c
I
b
I
ˆ
'
ˆ
a
I
c
I
ˆ
'
ˆ
DDAB:
,
,
(0
or
+60)
b
I
a
I
a
I
'
ˆ
'
ˆ
"
ˆ
c
I
b
I
b
I
'
ˆ
'
ˆ
"
ˆ
a
I
c
I
c
I
'
ˆ
'
ˆ
"
ˆ
The net effect of DDAB compensation is as follows:
c
I
b
I
a
I
a
I
'
'
ˆ
2
'
ˆ
"
ˆ
c
I
b
I
a
I
b
I
ˆ
2
ˆ
ˆ
"
ˆ
c
I
b
I
a
I
c
I
ˆ
ˆ
ˆ
2
"
ˆ
WYE:
,
,
(no
compensation)
a
I
a
I
ˆ
'
ˆ
b
I
b
I
ˆ
'
ˆ
c
I
c
I
ˆ
'
ˆ
Tables 3-2, 3-3, 3-4, and 3-5 illustrate how the various phase compensation factors are applied to
different winding and CT configurations.
The BE1-CDS240 can also compensate for phase “mismatch”. That is, if A phase of the incoming system
is connected to the transformer primary H1 and A phase of the secondary system is connected to X2, the
phases can be matched at the relay with this feature. Phase matching can be set through BESTCOMS,
under
General Operation, Transformer Setup, Transformer Phase Relationships
.
Settings for the current measurement functions are provided in Tables 3-2 through 3-5. These tables
indicate the transformer circuit, CT settings, and type of phase compensation applied for various
transformer applications. The settings are indicated on a per circuit basis. A circuit consists of one of the
transformer’s 3-phase windings and its corresponding set of 3-phase CT’s.
Table 3-2 indicates settings when applying the BE1-CDS240 in a non-transformer application. This table
should be used for inputs that are not part of the transformer’s circuit. Applying CT circuit #4 for auxiliary
ground is one possible example. The table also specifies the settings for a transformer case where all of
the 3-phase windings and all of the 3-phase CTs are connected in wye.
Tables 3-3 and 3-4 are applied when a combination of delta and wye connections are present in the
transformer and CT circuits. Table 3-3 is applied when only one type of delta connection is present in the
transformer and CT circuits, such as DAB or DAC. This table is used for the majority of applications. If the
application requires a combination of delta circuits, such as both DAB and DAC connections being
present, Table 3-4 is applied. The only exceptions are when all CT and winding connections are wye as
indicated above. Or, when one or more of the individual transformer windings are connected in delta or
zigzag and has its corresponding CTs connected in delta.
Table 3-5 is applied when one or more of the individual transformer windings is connected in delta or
zigzag and has its corresponding CTs connected in delta. The special connection can require up to two
delta compensations for the other windings depending on the circuit’s configuration.
Table 3-2. CT Input Circuit Settings for Non-transformer or Wye-only Application
BE1-CDS240 Settings
Compensation Applied
Transformer
Connection
CT Input
Connection
TX CT
Phase
Rotation
WYE NA WYE WYE
NONE
DAB NA DAB WYE
NONE
DAC NA DAC WYE
NONE
N/A
GND
(CTCKT 4)
NA
GND
WYE
N/A
All WYE
All
WYE
WYE WYE DAB NONE
Special case where all transformer windings and all CTs are connected in wye.
9365200990 Rev F
BE1-CDS240 Input and Output Functions
3-9
Summary of Contents for BE1-CDS240
Page 2: ......
Page 8: ...vi BE1 CDS240 Introduction 9365200990 Rev F This page intentionally left blank ...
Page 38: ...1 28 BE1 CDS240 General Information 9365200990 Rev F This page intentionally left blank ...
Page 40: ...ii BE1 CDS240 Quick Start 9365200990 Rev F This page intentionally left blank ...
Page 152: ...ii BE1 CDS240 Metering 9365200990 Rev F This page intentionally left blank ...
Page 226: ...iv BE1 CDS240 Application 9365200990 Rev F This page intentionally left blank ...
Page 286: ...ii BE1 CDS240 Security 9365200990 Rev F This page intentionally left blank ...
Page 290: ...9 4 BE1 CDS240 Security 9365200990 Rev F This page intentionally left blank ...
Page 292: ...ii BE1 CDS240 Human Machine Interface 9365200990 Rev F This page intentionally left blank ...
Page 306: ...10 14 BE1 CDS240 Human Machine Interface 9365200990 Rev F This page intentionally left blank ...
Page 308: ...ii BE1 CDS240 ASCII Command Interface 9365200990 Rev F This page intentionally left blank ...
Page 342: ...11 34 BE1 CDS240 ASCII Command Interface 9365200990 Rev F This page intentionally left blank ...
Page 349: ...Figure 12 5 Horizontal Rack Mount Front View 9365200990 Rev F BE1 CDS240 Installation 12 5 ...
Page 361: ...Figure 12 17 Typical DC Connection Diagrams 9365200990 Rev F BE1 CDS240 Installation 12 17 ...
Page 372: ...12 28 BE1 CDS240 Installation 9365200990 Rev F This page intentionally left blank ...
Page 468: ...13 92 BE1 CDS240 Testing and Maintenance 9365200990 Rev F This page intentionally left blank ...
Page 512: ...14 42 BE1 CDS240 BESTCOMS Software 9365200990 Rev F This page intentionally left blank ...
Page 544: ...ii BE1 CDS240 Terminal Communication 9365200990 Rev F This page intentionally left blank ...
Page 550: ...ii BE1 CDS240 Settings Calculations 9365200990 Rev F This page intentionally left blank ...
Page 578: ...D 28 BE1 CDS240 Settings Calculations 9365200990 Rev F This page intentionally left blank ...
Page 579: ......