SPECIFICATIONS 

5 Amp  CURRENT INPUTS 

Continuous rating: 
One second Rating: 

Saturation limit: 

Burden: 

1  Amp  CURRENT INPUTS 

Continuous rating: 

One second rating: 
Saturation limit: 

Burden: 

20A 
400A 
150A 

< 1 Omilliohms 

4A 

BOA 
30A 

<22milliohms 

PHASE AC VOLTAGE INPUTS 

Continuous rating: 

One second rating: 

Burden: 

Sensing: 

INPUT RANGES 

Voltage: 
Current: 

METERING ACCURACY 
Standards 

300V, Line to  Line 
600V,  Line to  Neutral 

<1VA@ 300Vac 

4-wire wye, 3 and 2% 

elements 

3-wire wye, 3 elements 

3-wire delta,  2112 and 2 

elements 

0-300Vac RMS 
0-3.0Aac,  1 A CT sec. 
0-15.0Aac, 5A CT sec. 

Meets or exceeds I EC 60687-1992 
Meets or exceeds IEEE C12.20 -1995 

At  50.0Hz 

or 

60.0Hz @ 25o  C (0.1 

lnom 

lmax> 

Voltage:  ±0.1% of reading 
Current:  ±0.1% of reading 

Watt (at ±0.8PF):  ±0.2% of reading 
VAR (at ±0.8PF):  ±0.2% of reading 
Maximum Temperature Error: 

± .005%, full scale per 

ac 

on V and I 

± .01 0%,  full scale per 

ac 

on W and vars 

Power Factor  (at  ±0.5PF):  0.55% of reading 
Pulse Inputs: 99.999% 
Frequency:  ±0.01% 

kWh,  kVARh,  and kVAh  MEASUREMENTS 

kWh (at ±0.8PF): 0.2% of reading 
kVARh (at ±0.8PF): 0.2% of reading 
kVAh (at ±0.8PF): 0.2% of reading 

A/D CONVERTER 

Sampling Rate: 

POWER SUPPLY 

Option 1: 

64/cycle, adjusted to 
input frequency 10-75Hz 

DC range 35 - 150V 

AC range 55 - 135V 

Option 2: 

Option 3: 

Burden: 

OUTPUT CONTACTS 

Contact 
Current 

30 Amps 
10 Amps 
0.3 Amps 

10 Amps 

Operating 

120Vac 
250Vac 
250Vdc 
30Vdc 

CONTROL INPUTS 

DC range 90 - 300V 

AC range 90 - 270V 

DC range 17 - 32V 

6 watts continuous, 
8 watts maximum with 
all outputs energized 

Operational 
Notes 
0.2 seconds sustained 

Continuous 

Break/Switched 

Continuous 

Wetting voltage range:  DC voltage same as 

control power supply 

option. 

Nominal Turn On/Off Voltage: 

Burden: 

COMMUNICATION PORTS 

P.S. Option 1:  33Vdc 
P.S. Option 2: 83Vdc 
P.S. Option 3: 16Vdc 

P.S. Option 1:  36KQ 
P.S. Option 2: 94KQ 
P.S. Option 3:  15KQ 

Baud rate: 

300 - 19200 

I RIG 

Supports IRIG Standard 200-98, format B002. 
Input Signal:  Demodulated (de level-shifted digital 
signal) 

Logic-High Voltage: 
Logic-Low Voltage 

Voltage Range: 
Resistance: 

DIELECTRIC STRENGTH 

3.5Vdc, minimum 
0.5Vdc, maximum 
-10 to  +10Vdc 

Non-linear, 
approximately 4 kohms 

at 3.5Vdc,  approximately 
3W at 20Vdc 

2000 Vac at 50/60 Hz in accordance with 
IEEE C37.90 and IEC 255-5 

SURGE WITHSTAND 

Qualified to IEEE C37.90.1-1989 

FAST TRANSIENT 

Qualified to IEEE C37.90.1-1989 

RADIO FREQUENCY INTERFERENCE (RFI) 

Qualified to IEEE C37.90.2-1995 

www 

. ElectricalPartManuals 

. com 

Summary of Contents for BE1-MMS100

Page 1: ...ors the status of input contacts from breakers targets switches etc Provides control outputs through built in interposing relays Available in fully drawout half rack case Two Basler Electric half rack...

Page 2: ...ng chips Integral HMI with 2x16 character display Wide range ac dc power supply options provide long holdup time to ride through dips on ac power source 1OOms with four output relays energized upon co...

Page 3: ...ied from 67 or 120Vac PTs 1 2 3 or 4 ac currents supplied from 1A or 5A CTs specified at time of order Meter input signals are supplied from PTs and CTs as paired sets of input signals Input signals a...

Page 4: ...the status input channels total of four channels available Pulse repetition rates of up to 20 per second on each channel are acceptable Inputs are scanned at 10 millisecond intervals A debouncing algo...

Page 5: ...y 48 125V AC DC Serial Number XXXXXXXXXX Unit Freeze Power Status Rx Tx Display 0 0 0 0 0 BE1 MMS COM RS 232 Figure 1 Front p anel of BE1 MMS100 LCD DISPLAY USAGE The LCD display is a 16 character by...

Page 6: ...e Configuration Circuit Active Analog CT Filter Circuit Circuit ISO l ISO f ISO l ISO l Power Supply Flash Memory Ground o Chassis HMI AID LCD Circuit Display Keypad ISO ISO Microprocessor r 1 ISO I W...

Page 7: ...N1 BUS A B c N IN2 IN3 IN4 IRIG PWR GND IN4 IRIG 1 BREAKER I I I I I 07 05 03 01 A 66Jv B2 w 3 B4 v 5 B6 7 sa y y y y ISO ISO ISO ISO I Oelta Wye I A B C N LINE 7 IN IC IB 71A Configuration Circuit LJ...

Page 8: ...elay Contacts Chan 1 Output Relay Contacts Chan 2 Output Relay Contacts Chan 3 Output Relay Contacts Chan 4 Output Relay Contacts Chan 5 Output Relay Contacts Chan 6 Total Harmonic Distortion Ph a Tot...

Page 9: ...WER SUPPLY Option 1 64 cycle adjusted to input frequency 10 75Hz DC range 35 150V AC range 55 135V Option 2 Option 3 Burden OUTPUT CONTACTS Contact Current 30 Amps 10 Amps 0 3 Amps 10 Amps Operating V...

Page 10: ...vironmentalTestProcedures Part 2 Test Z AD Composite Temperature Humidity Cyclic Test Note LCD Display is inoperative below 20 C VIBRATIONI SEISMIC Qualified to IEC255 21 1 Class 1 SHOCK Qualified to...

Page 11: ...ower supply H Half rack case 3 DNP 3 0 communications jBE1 MMS100 I 1 Amp Nominal Systems 3 3 phase sensing B 1 Amp Independent Gnd Input 5 Amp Nominal Systems E 5 Amp Independent Gnd Input STANDARDAC...

Page 12: ...ND ILLINOIS U S A 62249 PAE Les Pins 67319 Wasselonne Cedex FRANCE PHONE 618 654 2341 FAX 618 654 2351 PHONE 33 3 88 87 1010 FAX 33 3 88 87 0808 http www basler com info basler com Printed in U S A w...

Reviews: