4.2.10 Bitrate Command
Purpose:
To set the bitrate of the serial communications link. The bitrate is changed immediately after
the successful receipt of this command. (The default bitrate is 9600.)
Type:
This is a write only command.
Write Command:
Cmd-ID
R/W-Flag
Data Length
Data
0x44
0
4
4 Bytes
Response:
None
Data Format:
Byte 1
An ID that specifies the bitrate (see table below).
Byte 2
undefined - always write 0x00
Byte 3
undefined - always write 0x00
Byte 4
undefined - always write 0x00
ID
Bitrate
0x12
4800
0x13
9600
0x14
14400
0x15
19200
0x17
38400
0x19
57600
0x1A
76800
0x1B
115200
L
When changing the bitrate for serial communication, use the following procedure:
1. Issue the write command with the new bitrate.
2. Wait one second.
3. Change the bitrate on the serial port that the camera is using:
a) If you are using a Camera Link frame grabber, change the bit rate on the
frame grabber’s RS-644 serial port.
b) If you are using the camera with a k-BIC, change the bit rate on your PC’s
RS-232 serial port.
4. Resume communication.
At reset or power off/on, the camera will return to the 9600 bps setting.
Note:
The RS-644 serial port on some Camera Link frame grabbers will only support
a bitrate of 9600. If you are using a Camera Link frame grabber, check the grabber’s
documentation before attempting to change the bitrate.
Summary of Contents for L301kc
Page 1: ...Basler L301kc USER S MANUAL Document Number DA00051806 Release Date 13 July 2007...
Page 4: ......
Page 14: ...Introduction 1 6 Baslert L301kc DRAFT...
Page 20: ...Camera Interface 2 6 Basler L301kc DRAFT Figure 2 3 Camera Frame Grabber Interface...
Page 102: ...Configuring the Camera 4 32 Basler L301kc DRAFT...
Page 116: ...Troubleshooting 6 10 Basler L301kc DRAFT...
Page 118: ...Revision History ii Basler L301kc DRAFT...
Page 120: ...Feedback iv Basler L301kc DRAFT...
Page 124: ...Index viii Basler L301kc DRAFT...