Configuring the Camera
Basler L301kc
4-13
DRAFT
4.2.4.3 Timer 1
Purpose:
To set Timer 1 or to read the current Timer 1 setting. Timer 1 is used when the camera is
operating in ExSync programmable mode or in free-run mode. See Section
for details.
Type:
This is a read or write command.
Read Command:
Cmd-ID
R/W-Flag
Data Length
Data
0xA6
1
3
-
Response:
Cmd-ID
R/W-Flag
Data Length
Data
0xA6
0
3
3 Bytes
Write Command:
Cmd-ID
R/W-Flag
Data Length
Data
0xA6
0
2
3 Bytes
Response:
None
Data Format:
Byte 1
Low byte of the Timer 1 setting
Byte 2
Mid byte of the Timer 1 setting
Byte 3
High byte of the Timer 1 setting
Data Range:
The setting can range from 0x000002 to 0xFFFFFF.
This setting represents a multiplier and the actual value of Timer 1 is
determined by the following:
Timer 1 = setting x 0.0625 µs
To determine the value for this setting, simply divide your desired
Timer 1 value by 0.0625 µs. For example, if you wish to set Timer 1
to 2 µs, the calculation will be as shown below:
setting = 2 µs / 0.0625 µs
setting = 32
In this case, the setting would be 32 (decimal) which translates to a
hexadecimal setting of 0x000020.
Summary of Contents for L301kc
Page 1: ...Basler L301kc USER S MANUAL Document Number DA00051806 Release Date 13 July 2007...
Page 4: ......
Page 14: ...Introduction 1 6 Baslert L301kc DRAFT...
Page 20: ...Camera Interface 2 6 Basler L301kc DRAFT Figure 2 3 Camera Frame Grabber Interface...
Page 102: ...Configuring the Camera 4 32 Basler L301kc DRAFT...
Page 116: ...Troubleshooting 6 10 Basler L301kc DRAFT...
Page 118: ...Revision History ii Basler L301kc DRAFT...
Page 120: ...Feedback iv Basler L301kc DRAFT...
Page 124: ...Index viii Basler L301kc DRAFT...