7.
Test the lift on dry ground using the Up/Down Switch
and the Key Fob Transmitters. Inspect the system
for leaks.
1.
The Hydraulic Power Unit will arrive fully assembled.
Make sure all the connections are snug to prevent
leaks or loss of power to the unit.
NOTE:
Ensure battery cables are correctly connected
4.
Slide the Hydraulic Hose Assembly through the
access hole in the side of the fiberglass Enclosure
and attach the ends to their corresponding
Quick Couplers.
and their terminals are tight (use a wrench).
Ensure each Quick Coupler is
completely seated and
tight
with
no gap at the connection joint.
Connection must be
tight
to open internal
check valve and allow fluid to flow. USE PLIERS
DO NOT SUBMERSE
Keep inside dry
5. Plug the cable from the Solar Panel into the connector
with yellow & black wires that comes from the Solar
Controller (shown above left).
NO GAP!
Prevent unauthorized use -
KEEP BOX LOCKED
2.
COMPLETE POWER PACKAGE
#
H653-0013
power
switch
POSITIVE BATTERY
CABLE (RED)
#
R711-1010
NEGATIVE BATTERY
CABLE (BLACK)
#
R711-1005
HOSE ASSEMBLY
#
H123-0001
remote
receiver
up/down
switch
MALE QUICK COUPLER
#
H700-0020
FEMALE QUICK COUPLER
#
H700-0019
6.
Read the Operating Instructions in the Owner’s Manual.
NOTE:
REMOVE SHIPPING PLUG IN
RESERVOIR AND REPLACE
WITH BREATHER PLUG
BEFORE START-UP
NOTE:
REMOVE SHIPPING PLUG IN
RESERVOIR AND REPLACE
WITH BREATHER PLUG
BEFORE START-UP
3.
Replace the reservoir tank shipping plug with the
included breather plug.
solar
controller
one
inch
hydraulic fluid level with
lift in DOWN position
breather
cap
REPLACE SHIPPING PLUG
WITH BREATHER CAP
(ATTACHED TO CONTROL PANEL)
28
# R811-0010
Remote Control Receiver
with Fobs
Remote Key Fobs
POWER UNIT
ASSEMBLY
#
H603-0003
Please order replacement parts by PART NO. and DESCRIPTION
pre-wired
with wiring
harness
Hydraulic Fluid (quart)
BATTERY SAFETY IS IMPORTANT
Follow all battery manufacturer’s
warnings and safety information.
Padlock
not included
SOLAR PANEL ASSEMBLY
#
R281-0004
ENCLOSURE
#
C243-0003
# R812-0011
# Y354-0001
# R283-0002
Solar Controller
Connect to Solar Panel
Connected
NOTE:
REMOVE SHIPPING PLUG IN
RESERVOIR AND REPLACE
WITH BREATHER PLUG
BEFORE START-UP
NOTE:
REMOVE SHIPPING PLUG IN
RESERVOIR AND REPLACE
WITH BREATHER PLUG
BEFORE START-UP
CONTROL PANEL
ASSEMBLY
#
R815-0008
STANDARD POWER UNIT
STANDARD POWER UNIT
4
5
NOTE: always turn unit OFF when not in use
Install a Group 31 Deep Discharge AGM Battery as
shown above. Be sure to connect the Red Battery
Cable to th e positive terminal and the Black Battery
Cable to the negative terminal.
OIL INJECTED INTO THE SKIN FROM HIGH
PRESSURE LEAKS IN HYDRAULIC SYSTEMS
CAN CAUSE SEVERE INJURY. MOST DAMAGE
OCCURS DURING THE FIRST FEW HOURS.
SEEK MEDICAL ATTENTION IMMEDIATELY.
SURGICAL REMOVAL OF OIL MAY BE
NECESSARY.