Operation and Control System
A: R82GB0FA.PMD
B: R82DE0FA.P65
E: 080403 / T. Weiß
G: 200103 / TCS
Section 5.5
Page 37
?
58 Axis in Bpos.
Effect:
This error message is sent out if the auxiliary
axes are not in the specified position when the
reference movement is started.
To remedy:
Switch to Manual mode and move the axes to
their basic position.
59 Compressed air monit.
Possible cause:
Compressed air dropped below 3 bar (44 psi).
Effect:
-
Current servo axis stops moving.
-
Enable signals to IMM disappear.
-
Movement of all pneumatic axes and
gripper functions is blocked.
To remedy:
-
Check compressed air.
-
Press the START button on the MCD
(System continues in Automatic mode).
61 Warn.Con. full 1
Cause:
Signal indicates that the ”Warning Conveyor full”
limit switch has been reached.
Effect:
-
Error message is only an instruction. It
need not be confirmed.
To remedy:
-
Clear conveyor.
-
Check limit switches.
62 Conv. full 1
Cause:
Conveyor was stopped by the limit switch
(conveyor stop).
Effect:
-
Conveyor is stopped.
-
Error need not be confirmed.
To remedy:
-
Clear conveyor.
-
Check limit switches.
Summary of Contents for UNILOG B2
Page 4: ...A PB2GBI1A P65 B PB2DEI1A P65 E 180202 Ruder G 190202 G Krajnik Section IN1 Page 2 Index...
Page 10: ......
Page 14: ...A R82GB0AA PDM B R82DE0AA PDM E 080403 T Wenger G 020403 TCS Section 1 Page 4 General...
Page 16: ...A R82GB0AA PDM B R82DE0AA PDM E 080403 T Wenger G 020403 TCS Section 1 Page 6 General...
Page 32: ...A R82GB0CA PDM B R82DE0CA PDM E 080403 T Wenger G 020403 TCS Section 3 Page 10 Specifications...
Page 118: ...A R82GB0HA PMD B R82DE0HA PMD E 080403 T Wenger G 020403 TCS Section 7 Page 16 Maintenance...