background image

Andromeda MAX VAP mod.2009 v1.1 

pag. 2 

gennaio 2009 

 

2.

 

IMPORTANT 

 

Before installing ANDROMEDA MAX VAP it is necessary to set up the following facilities 

next to where it will be installed: 
 

1.

 

a  water  connection  (tap  with  hose  holder);  ANDROMEDA  MAX  VAP  will  be   
connected to the tap with hose holder named “WATER INLET” 

(fig. 1)

 by means of 

a rubber hose which must have a pressure resistance of at least 10 ATM. (diameter 

of water inlet 8/13 mm) and which must be fixed tightly with 2 hose clamps. 

N.B.:

 

before inserting the rubber hose into ANDROMEDA MAX VAP hose holder, you must 

exhaust a few litres of water in order to clean the conduit; 

2.

 

a protected electrical outlet suitable to ANDROMEDA MAX VAP power. 

 

 

3.

 

OPENING OF PACKAGE 

 

1.

 

Open  the  box  containing  ANDROMEDA  MAX  VAP  from  the  upper  side  marked  as 

ALTO, take out the instructions handbook and read it carefully.

 

2.

 

Remove  ANDROMEDA  MAX  VAP  from  the  box,  insert  the  cable  support  into  the 

special hole, connect the iron plug and the steam hose, fix the iron cables to the 
cable support hook and place the iron on the iron rest 

(fig. 1)

.

 

 

 

4.

 

“STANDARD” & “STAND-BY” MODE 

 
By turning on the main switch, the machine is in 

“stand-by”

 mode (red led on). This 

mode allows access to the SET menu in order to set some functions (e.g.: language, 
periodical maintenance warnings etc. – see point 6): 

 

 

Electronic  card  in 

stand-by

  mode.  If  maintenance  should  be  required 

(filter  cleaning,  cover  changing,  …)  a  warning  will  inform  you  which 

intervention  is  needed.  The  warning  will  disappear  once  the  intervention 
has been done and the RESET key has been pressed (see point 9).  

 
By pressing the start key, the machine is in 

“standard”

 mode. This allows to set the 

ironing  functions  (e.g.:  speed  of  motors,  temperature  of  ironing  board,  iron 
functioning etc.): 

 

Start key. Electronic card in 

standard 

mode. 

 

To temporarily turn off the machine you may press the start key: the machine will go 

into  stand-by  mode  and  the  red  led  will  turn  on.  However,  the  electronic  card  will 
continue to receive power from the mains supply.   

At the end of each working day we suggest to always turn the machine off by 
using the main switch (fig. 1).  

 

WARNING:

  the  electronic  card  automatically  performs  a  check  of  the  software 

installed. If an error or fault is found the “safety” device blocks the electronic card and 

does  not  allow  normal  functioning.  “

SOFTWARE  UPDATE  NEEDED

”  will  be  displayed. 

Contact the Authorized Service Centre to update the software.  

Summary of Contents for ANDROMEDA MAX VAP 2009

Page 1: ...W 1100 W 1600 SUCTION BLOWING POWER 0 5hp 0 5hp 0 5hp 0 5hp PUMP POWER 0 7 hp 0 7 hp BOILER CAPACITY 10 L 10 L IRONING ENDURANCE CONTINUOUS CONTINUOUS OPERATING STEAM PRESSURE 5 BAR 5 BAR WEIGHT KG 1...

Page 2: ...urning on the main switch the machine is in stand by mode red led on This mode allows access to the SET menu in order to set some functions e g language periodical maintenance warnings etc see point 6...

Page 3: ...UM SPEED will be displayed Blowing speed increase and decrease keys Adjustable from position 0 motor turned off to position 5 maximum speed BLOWING SPEED will be displayed Boiler on off key When the b...

Page 4: ...ater for a long time Check that water comes out of the pipe connected to the water supply Turn off the main switch wait for 5 seconds and turn the machine on again If the problem reoccurs contact Auth...

Page 5: ...t will be memorized so that they will automatically be activated once the machine is switched on again N B the blowing and vacuum speeds are never memorized and start from maximum speed every time the...

Page 6: ...displayed 1 Gain access to SET 2 find RESET WARNINGS press OK and find PROBE 3 press OK RESET and then OK 4 ESC to exit the SET menu N B the warnings may be reset only if the are shown on the display...

Page 7: ...pressure N B SUBSTITUTE FUSES WITH INTERCHANGEABLE ONES AND WITH THE SAME PERFORMANCE 1 Arm 2 Contactor 3 Pistol 4 Iron 2 5 Iron 1 6 Pump 7 Blowing motor 8 Vacuum motor 9 Light steam aux 10 Board resi...

Page 8: ...he garments we suggest to keep the foot on the pedal for vacuum a bit longer 2 For delicate black and blue garments we suggest to use an anti sheen shoe 3 During ironing operation always put the iron...

Page 9: ...us for the operator 1 using ANDROMEDA MAX VAP for different purposes other than ironing 2 using ANDROMEDA MAX VAP without turning the water tap on or when the aqueduct cannot supply water 3 using ANDR...

Page 10: ...per day 5 days a week In these conditions the machine is expected to function for 7 years 18 CLEANING OF WATER FILTER The cleaning of the filter is to be done whenever the warning is displayed If the...

Page 11: ...ly made of iron material and must therefore be disposed of in proper warehouses for used iron recovery The crossed rubbish bin symbol indicates that components of ANDROMEDA MAX VAP must be disposed of...

Reviews: