Andromeda MAX VAP mod.2009 v1.1
pag. 2
gennaio 2009
2.
IMPORTANT
Before installing ANDROMEDA MAX VAP it is necessary to set up the following facilities
next to where it will be installed:
1.
a water connection (tap with hose holder); ANDROMEDA MAX VAP will be
connected to the tap with hose holder named “WATER INLET”
(fig. 1)
by means of
a rubber hose which must have a pressure resistance of at least 10 ATM. (diameter
of water inlet 8/13 mm) and which must be fixed tightly with 2 hose clamps.
N.B.:
before inserting the rubber hose into ANDROMEDA MAX VAP hose holder, you must
exhaust a few litres of water in order to clean the conduit;
2.
a protected electrical outlet suitable to ANDROMEDA MAX VAP power.
3.
OPENING OF PACKAGE
1.
Open the box containing ANDROMEDA MAX VAP from the upper side marked as
ALTO, take out the instructions handbook and read it carefully.
2.
Remove ANDROMEDA MAX VAP from the box, insert the cable support into the
special hole, connect the iron plug and the steam hose, fix the iron cables to the
cable support hook and place the iron on the iron rest
(fig. 1)
.
4.
“STANDARD” & “STAND-BY” MODE
By turning on the main switch, the machine is in
“stand-by”
mode (red led on). This
mode allows access to the SET menu in order to set some functions (e.g.: language,
periodical maintenance warnings etc. – see point 6):
Electronic card in
stand-by
mode. If maintenance should be required
(filter cleaning, cover changing, …) a warning will inform you which
intervention is needed. The warning will disappear once the intervention
has been done and the RESET key has been pressed (see point 9).
By pressing the start key, the machine is in
“standard”
mode. This allows to set the
ironing functions (e.g.: speed of motors, temperature of ironing board, iron
functioning etc.):
Start key. Electronic card in
standard
mode.
To temporarily turn off the machine you may press the start key: the machine will go
into stand-by mode and the red led will turn on. However, the electronic card will
continue to receive power from the mains supply.
At the end of each working day we suggest to always turn the machine off by
using the main switch (fig. 1).
WARNING:
the electronic card automatically performs a check of the software
installed. If an error or fault is found the “safety” device blocks the electronic card and
does not allow normal functioning. “
SOFTWARE UPDATE NEEDED
” will be displayed.
Contact the Authorized Service Centre to update the software.