5.
USE OF KEYS - STANDARD MODE
Verify that the electronic card is in “standard” mode.
°C
UP
DOWN
“Ironing board temperature” increase and decrease keys
.
Adjustable from
0° C to 90° C (or 120° C on steaming models). Upon pressing one of the
keys, the temperature set by the operator will be displayed (
IRONING
BOARD TEMP. SETTING
). If no key is not pressed after 5 seconds, the real
temperature of the ironing board will be displayed (
IRONING BOARD
TEMPERATURE
).
RESET
“Vacuum speed” increase and decrease keys. Adjustable from position 0
(motor turned off) to position 5 (maximum speed).
VACUUM SPEED
will be
displayed.
“Blowing speed” increase and decrease keys. Adjustable from position 0
(motor turned off) to position 5 (maximum speed).
BLOWING SPEED
will be
displayed.
“Boiler” on/off key. When the boiler is functioning, the led is on.
“Light” on/off key. (accessory available upon request). When the light is
functioning, the led is on.
“Steam pistol” or “steam brush” on/off keys. (accessory available upon
request). When the pistol or brush are functioning, the led is on
.
ESC
OK
“Iron 1 or 2” on/off keys. When the iron is functioning, the led is
on.
6.
USE OF KEYS - STAND-BY MODE
Verify that the electronic card is in “stand-by” mode
SET
OK
ESC
SET
By pressing both keys simultaneously while the electronic
card is in stand-by mode, it allows you to enter and exit
the SET menu.
OK
OK
Key to confirm the choice made within the SET menu.