Indicates  that  the  maximum  number  of  hours  set  for  the  cleaning  of  the 

boiler’s  probe  has  been  exceeded.  Clean  the  probe  and  reset  the  warning 

(see  SET & RESET )

 

 

Indicates  an  anomalous  overheating    of  the  boiler.  WARNING:  A  safety 

device  will  block  the  heating  of  the  water  inside  the  boiler.  Turn  off    the 
main  switch  and  wait  for  half  an  hour.  If  the  problem  reoccurs,  contact 

Authorized Service Centre. 

 

 

 

8.

 

CONNECTION AND STARTING 

 

1.

 

Connect the rubber hose to the hose holder indicated as WATER INLET placed on 
ANDROMEDA MAX VAP 

(fig. 1)

 and turn the water tap on. For ANDROMEDA MAX 

VAP equipped with water tank, you just have to fill it and connect the machine to 
the  mains  supply. 

N.B.:  make  sure  there  is  always  water  inside  the  water 

tank. 

2.

 

Connect the power supply cable to a protected outlet with earth protector switch, 
with  observance  of  the  law  in  force  and  a  voltage  suitable  to  ANDROMEDA  MAX 

VAP. 

3.

 

Turn  on  the  main  switch  and  set  the  electronic  card  in  “standard”  mode.  Select 

which functions are to be activated and which to be deactivated (iron, boiler etc.). 
If the main switch is turned off, the functions previously set will be memorized so 

that  they  will  automatically  be  activated  once  the  machine  is  switched  on  again. 

N.B.  the  blowing  and  vacuum  speeds  are  never  memorized  and  start  from 
maximum speed every time the electronic card is switched on. 

4.

 

Adjust the  heating  of  the  ironing  board  by  setting  it on  the  desired temperature. 
When  using  the  steaming  pedal,  it is  suggested  to  set  the  heating  of  the  ironing 

board on maximum temperature (see chapter 5). 

5.

 

Check that the boiler has reached the ideal pressure for ironing (led of boiler icon 
must be turned off and the manometer must be 5 Bar – 

fig. 1

). Seize the iron by 

the  cork handle  and  press the micro-switch 3  or 4  times 

(fig. 4)

,  so  that  steam 

comes out: this operation must be carried out in order to heat up the hoses which 

take steam to the iron. In this way you prevent also the falling of small drops of 

water  on  garments  (iron  must  always  be  held  in  such  a  way  as  not  to  harm 
operator, that is with iron always pointed downwards). 

6.

 

To  adjust the steam flux  you  must work  on the  steam  adjustment  tap  placed  on 
the solenoid valve 

(fig. 1: solenoid valve)

7.

 

After this, ANDROMEDA MAX VAP is ready for use.  

 

 

9.

 

SET & RESET  

 

 

To gain access to the SET menu, the electronic card must be in “stand-

by” mode. Press both keys simultaneously as shown on the left. To exit 

the SET mode, press both keys simultaneously or wait for 5 seconds 
 

OK

ESC

SET

 

Summary of Contents for ANDROMEDA MAX VAP 2009

Page 1: ...W 1100 W 1600 SUCTION BLOWING POWER 0 5hp 0 5hp 0 5hp 0 5hp PUMP POWER 0 7 hp 0 7 hp BOILER CAPACITY 10 L 10 L IRONING ENDURANCE CONTINUOUS CONTINUOUS OPERATING STEAM PRESSURE 5 BAR 5 BAR WEIGHT KG 1...

Page 2: ...urning on the main switch the machine is in stand by mode red led on This mode allows access to the SET menu in order to set some functions e g language periodical maintenance warnings etc see point 6...

Page 3: ...UM SPEED will be displayed Blowing speed increase and decrease keys Adjustable from position 0 motor turned off to position 5 maximum speed BLOWING SPEED will be displayed Boiler on off key When the b...

Page 4: ...ater for a long time Check that water comes out of the pipe connected to the water supply Turn off the main switch wait for 5 seconds and turn the machine on again If the problem reoccurs contact Auth...

Page 5: ...t will be memorized so that they will automatically be activated once the machine is switched on again N B the blowing and vacuum speeds are never memorized and start from maximum speed every time the...

Page 6: ...displayed 1 Gain access to SET 2 find RESET WARNINGS press OK and find PROBE 3 press OK RESET and then OK 4 ESC to exit the SET menu N B the warnings may be reset only if the are shown on the display...

Page 7: ...pressure N B SUBSTITUTE FUSES WITH INTERCHANGEABLE ONES AND WITH THE SAME PERFORMANCE 1 Arm 2 Contactor 3 Pistol 4 Iron 2 5 Iron 1 6 Pump 7 Blowing motor 8 Vacuum motor 9 Light steam aux 10 Board resi...

Page 8: ...he garments we suggest to keep the foot on the pedal for vacuum a bit longer 2 For delicate black and blue garments we suggest to use an anti sheen shoe 3 During ironing operation always put the iron...

Page 9: ...us for the operator 1 using ANDROMEDA MAX VAP for different purposes other than ironing 2 using ANDROMEDA MAX VAP without turning the water tap on or when the aqueduct cannot supply water 3 using ANDR...

Page 10: ...per day 5 days a week In these conditions the machine is expected to function for 7 years 18 CLEANING OF WATER FILTER The cleaning of the filter is to be done whenever the warning is displayed If the...

Page 11: ...ly made of iron material and must therefore be disposed of in proper warehouses for used iron recovery The crossed rubbish bin symbol indicates that components of ANDROMEDA MAX VAP must be disposed of...

Reviews: