Indicates that the maximum number of hours set for the cleaning of the
boiler’s probe has been exceeded. Clean the probe and reset the warning
(see SET & RESET )
Indicates an anomalous overheating of the boiler. WARNING: A safety
device will block the heating of the water inside the boiler. Turn off the
main switch and wait for half an hour. If the problem reoccurs, contact
Authorized Service Centre.
8.
CONNECTION AND STARTING
1.
Connect the rubber hose to the hose holder indicated as WATER INLET placed on
ANDROMEDA MAX VAP
(fig. 1)
and turn the water tap on. For ANDROMEDA MAX
VAP equipped with water tank, you just have to fill it and connect the machine to
the mains supply.
N.B.: make sure there is always water inside the water
tank.
2.
Connect the power supply cable to a protected outlet with earth protector switch,
with observance of the law in force and a voltage suitable to ANDROMEDA MAX
VAP.
3.
Turn on the main switch and set the electronic card in “standard” mode. Select
which functions are to be activated and which to be deactivated (iron, boiler etc.).
If the main switch is turned off, the functions previously set will be memorized so
that they will automatically be activated once the machine is switched on again.
N.B. the blowing and vacuum speeds are never memorized and start from
maximum speed every time the electronic card is switched on.
4.
Adjust the heating of the ironing board by setting it on the desired temperature.
When using the steaming pedal, it is suggested to set the heating of the ironing
board on maximum temperature (see chapter 5).
5.
Check that the boiler has reached the ideal pressure for ironing (led of boiler icon
must be turned off and the manometer must be 5 Bar –
fig. 1
). Seize the iron by
the cork handle and press the micro-switch 3 or 4 times
(fig. 4)
, so that steam
comes out: this operation must be carried out in order to heat up the hoses which
take steam to the iron. In this way you prevent also the falling of small drops of
water on garments (iron must always be held in such a way as not to harm
operator, that is with iron always pointed downwards).
6.
To adjust the steam flux you must work on the steam adjustment tap placed on
the solenoid valve
(fig. 1: solenoid valve)
.
7.
After this, ANDROMEDA MAX VAP is ready for use.
9.
SET & RESET
To gain access to the SET menu, the electronic card must be in “stand-
by” mode. Press both keys simultaneously as shown on the left. To exit
the SET mode, press both keys simultaneously or wait for 5 seconds
OK
ESC
SET