Andromeda MAX VAP mod.2009 v1.1
pag. 7
gennaio 2009
10.
SUBSTITUTION OF FUSES
Substitution of fuses is required when a short circuit or an overload occurs. Checking of the
fuses is the first thing to be done in case a warning should be displayed.
WARNING!: before replacing the fuse it is important to eliminate the cause which determined
its breakage.
To gain access to the fuses the main switch must be on pos. “0” and the four screws
are to be unscrewed from the panel. The positioning of the fuses is indicated in
Fig. 2
.
In order to replace a fuse, unscrew it by using a screwdriver and being careful to
exert only a slight pressure. N.B.: SUBSTITUTE FUSES WITH INTERCHANGEABLE
ONES AND WITH THE SAME PERFORMANCE.
1. Arm
2. Contactor
3. Pistol
4. Iron 2
5. Iron 1
6. Pump
7. Blowing motor
8. Vacuum motor
9. Light, steam, aux
10. Board resistance
11.
SUBSTITUTION OF POWER CURRENT FUSES
The power current fuses protect the whole machine and are
situated near the electronic card. If the fuses of the electronic
card have been checked and are not damaged, check the
power current fuses and replace them if necessary.
To gain access to the fuses the main switch must be on pos.
“0” and the four screws are to be unscrewed from the panel.
N.B.: SUBSTITUTE FUSES WITH INTERCHANGEABLE ONES
AND WITH THE SAME PERFORMANCE.
12.
COMPULSORY
Fig. 2
230V 2A
1
230V 2A
2
3
230V 4A
4
230V 5A
5
230V 5A
6
230V 4A
7
230V 4A
8
230V 4A
9
230V 4A
10
230V 15A
Power current fuses
400V - 32A