1.

 

Use only tap water.

 

2.

 

Never add additives to water. 

3.

 

Empty  the  boiler  once  a  week,  making  sure  that  boiler  pressure  is  not 

over 0,5 BAR 

(fig. 1: manometer). 

To carry

 

out this operation, turn the exhaust 

tap slowly: we advise you to wear gauntlets against possible burns. 

N.B.

 Carry out 

this operation only when the boiler is cold and the plug  is disconnected from the 

mains.  

4.

 

Never leave hot iron on ANDROMEDA MAX VAP ironing board. 

5.

 

Connect ANDROMEDA to a suitable and protected outlet. 

6.

 

After ironing is over, switch ANDROMEDA MAX VAP off and turn the water tap off; 

always remember to turn the water tap on before switching on the machine again 

(only for ANDROMEDA MAX VAP connected to the aqueduct). 

7.

 

Always keep children away from ANDROMEDA MAX VAP, both when it is on and off. 

8.

 

Make sure that during cold season the tubes connecting ANDROMEDA MAX VAP to 
the water supply do not freeze. 

9.

 

If the machine is not used for a long period of time, turn it off by using the main 

switch. 

 

13.

 

IRONING 

 

1.

 

Run  the  iron  on  the  garments,  pressing  the  micro-switch 

(fig.  4)

  at  regular 

intervals and at the same time pressing the pedal for vacuum 

(fig. 1)

. In order to 

dry  the  garments,  we  suggest  to  keep  the  foot  on  the  pedal  for  vacuum  a  bit 
longer. 

2.

 

For delicate, black and blue garments, we suggest to use an anti-sheen shoe. 

3.

 

During ironing operation, always put the iron on its iron rest and pay attention to 
the position of the cables: if they twine or get in touch with the ironing board, they 

might cause short circuits. 

4.

 

For dry ironing it is possible to adjust the thermostat 

(fig. 3)

 on different positions 

according to the type of fabric (check garment label).  

5.

 

For  steam ironing  you  should  adjust the  thermostat on  “cotton”  position 

(fig.  3)

 

(suitable for all types of fabrics). 

6.

 

ANDROMEDA  MAX  VAP  is  equipped  with  a  pedal  for  steaming  on  ironing  board 
(fig.1).  This  pedal  is  needed  to  provide  steam  to  the  ironing  board  and  is  used 

mainly for knitwear.  Once the pedal for steaming has been pressed, immediately 
use  the  pedal for vacuum  to  dry  the  humid garment. A  pedal for  blowing  is  also 

available for those garments which require blowing. 

N.B

. If steaming is used very 

often,  some  water  may  come  out  of  the  air  outlet  of  the  motor.  It  is  therefore 
necessary  to  connect  it  to  an  air  outlet  pipe.  N.B.  Upon  steaming,  set  the 

temperature of the ironing board at 120°C.   

7.

 

ANDROMEDA  MAX  VAP  is  equipped  with  an  air  deviation  (fig.  1)  which  may  be 

closed, thus increasing the vacuum power on the sleeve ironing arm.  

 

 

Fig. 4

 

Fig. 3

 

ELECTRICAL
WIRE

THERMOSTAT

MICROSWITCH
FOR IRON

STEAM HOSE

 

Summary of Contents for ANDROMEDA MAX VAP 2009

Page 1: ...W 1100 W 1600 SUCTION BLOWING POWER 0 5hp 0 5hp 0 5hp 0 5hp PUMP POWER 0 7 hp 0 7 hp BOILER CAPACITY 10 L 10 L IRONING ENDURANCE CONTINUOUS CONTINUOUS OPERATING STEAM PRESSURE 5 BAR 5 BAR WEIGHT KG 1...

Page 2: ...urning on the main switch the machine is in stand by mode red led on This mode allows access to the SET menu in order to set some functions e g language periodical maintenance warnings etc see point 6...

Page 3: ...UM SPEED will be displayed Blowing speed increase and decrease keys Adjustable from position 0 motor turned off to position 5 maximum speed BLOWING SPEED will be displayed Boiler on off key When the b...

Page 4: ...ater for a long time Check that water comes out of the pipe connected to the water supply Turn off the main switch wait for 5 seconds and turn the machine on again If the problem reoccurs contact Auth...

Page 5: ...t will be memorized so that they will automatically be activated once the machine is switched on again N B the blowing and vacuum speeds are never memorized and start from maximum speed every time the...

Page 6: ...displayed 1 Gain access to SET 2 find RESET WARNINGS press OK and find PROBE 3 press OK RESET and then OK 4 ESC to exit the SET menu N B the warnings may be reset only if the are shown on the display...

Page 7: ...pressure N B SUBSTITUTE FUSES WITH INTERCHANGEABLE ONES AND WITH THE SAME PERFORMANCE 1 Arm 2 Contactor 3 Pistol 4 Iron 2 5 Iron 1 6 Pump 7 Blowing motor 8 Vacuum motor 9 Light steam aux 10 Board resi...

Page 8: ...he garments we suggest to keep the foot on the pedal for vacuum a bit longer 2 For delicate black and blue garments we suggest to use an anti sheen shoe 3 During ironing operation always put the iron...

Page 9: ...us for the operator 1 using ANDROMEDA MAX VAP for different purposes other than ironing 2 using ANDROMEDA MAX VAP without turning the water tap on or when the aqueduct cannot supply water 3 using ANDR...

Page 10: ...per day 5 days a week In these conditions the machine is expected to function for 7 years 18 CLEANING OF WATER FILTER The cleaning of the filter is to be done whenever the warning is displayed If the...

Page 11: ...ly made of iron material and must therefore be disposed of in proper warehouses for used iron recovery The crossed rubbish bin symbol indicates that components of ANDROMEDA MAX VAP must be disposed of...