Barbara 27 da tavolo mod. 2010
13
2016
9.
GOOD FUNCTIONING
BARBARA 27 PORTABLE MODEL was designed and manufactured for the ironing of
domestic garments. It can be used maximum 20 hrs. per week or 80 hrs. per month
(subdivided in many times).
10.
INTERVENTIONS AND SMALL REPAIRS
1.
It is advisable to empty the boiler every 2 or 3 times you use it.
2.
It is advisable to replace the gasket of the safety valve plug (use only original
gaskets) every 1200 hrs. of lighting or maximum 2 years, or earlier if it is
damaged. Carry out this operation when the machine is switched off and cold.
3.
If the electric wire is damaged, replace it immediately. The wire is supplied by the
manufacturer or authorized service centres.
11.
COMPULSORY PERIODICAL MAINTENANCE
(To be carried out exclusively by assistance centres or by the manufacturer)
It is recommended to replace:
1.
the internal safety valve every 2100 hrs. of ironing or maximum 3 years;
2.
the internal thermostats every 2100 hrs. of ironing or maximum 3 years;
3.
steam tube and iron cable once they seem damaged (fig. 4);
4.
the safety valve plug every 2500 hrs. of ironing or maximum 3 years (fig. 3).
It is recommended also to clean the boiler from limestone every 2500 hrs. of ironing
or maximum 3 years.
12.
ELECTRICAL RISKS
The following situations are considered dangerous for the operator:
1.
earth protector switch is activated when turning on the machine;
2.
using BARBARA 27 PORTABLE MODEL during thunderstorms;
3.
using BARBARA 27 PORTABLE MODEL without proper protection for feet (without
shoes
…
) or with wet hands and feet;
4.
damage of electric wires;
5.
when the electric wire touches hot parts of the machine;
6.
loss of water from iron or iron overheating (fig. 4);
7.
washing or cleaning the iron using water (fig. 4);
8.
loss of water from the machine;
9.
filling the boiler when the machine is switched on.
13.
MECHANICAL RISKS
The following situations are considered dangerous for the operator:
1.
using BARBARA 27 PORTABLE MODEL for different purposes other than ironing;
2.
replacing the safety valve plug gasket with non-original gaskets.