background image

Gea V.06 

11 

2018 

 
The  sanitizing  cabinet  is  able  to  indicate  to  the  centralized  coin  mechanism  that  a 

program is in progress (machine busy), by sending a 24 Vac voltage signal. 
When the machine is free, the signal is 0 Vac. 

 
 

17.

 

ELECTRICAL RISKS

 

 

The operator must pay attention to the following situations defined as hazardous from 

the electrical point of view: 
 

1.

 

when the differential switch (circuit breaker) intervenes; 

2.

 

when using the machine during a thunderstorm; 

3.

 

when using the machine without proper feet protection (without shoes...) or with 
wet hands or feet; 

4.

 

when electric cables are damaged; 

5.

 

when  the  machine  is  not  connected  to  proper  grounding  according  to  the 
regulations in force; 

6.

 

when replacing lamps and/or ballasts or any material with non-genuine parts.

 

 

 
18.

 

MECHANICAL RISKS  

 

The operator must pay attention to the following situations defined as hazardous from 
the mechanical point of view: 

 

1.

 

when using the machine for a purpose different than the intended one. 

 

 

19.

 

INTERVENTIONS AND SMALL REPAIRS

 

 

1.

 

Remove, when necessary, the dust from the lamps and the grille using a vacuum 

cleaner  (fig.  2).  Do  not  disconnect  or  reverse  the  electrical  connection  of  the 
lamps in any way. 

2.

 

If the power cord is damaged, replace it immediately. The cable is available at the 
manufacturer  or  the  technical  assistance  service.  Do  not  use  the  appliance  with 

damaged cable. 

 

 

20.

 

SOLUTIONS TO POSSIBLE PROBLEMS

 

 

The most common problems that can occur and their possible solutions are shown in 
the table below. Before intervening on the live parts, it is recommended to disconnect 

the machine from the power supply. 
 

 

 
 

 
 

 
 

Summary of Contents for GEA

Page 1: ...36028 Rossano Veneto VI ITALY 39 0424 549027 39 0424 549007 www battistellag it info battistellag it This manual is the property of BATTISTELLA B G S r l Any reproduction is prohibited The Company res...

Page 2: ...TOP AND DOOR OPENING 8 11 DOOR OPENING CLOSING 8 12 ADJUSTABLE SHELF 9 13 OZONE BLASTER FAULT 9 14 ABNORMAL SHUTDOWN OF THE PROGRAM NO ELECTRICITY 9 15 CHANGE LANGUAGE 10 16 PLUG CONNECTION ONLY THE M...

Page 3: ...e the product in a manner different than the one specified in this manual 1 MACHINE FEATURES MODEL GEA ELECTRICAL POWER 230 V 50 60 Hz TOTAL INSTALLED POWER 143 W BLOWING MOTOR POWER 73 W OZONE LAMP P...

Page 4: ...not play with the device To make the hazards more obvious adhesive symbols whose meaning is explained below are placed on the critical points of the machine 3 PACKAGING OPENING 1 When receiving the m...

Page 5: ...operation 8 Keep the power supply cord away from hot surfaces and make sure it is not crushed by doors or trampled 9 The machine must be positioned so that there is a distance of no less than 50 cm be...

Page 6: ...shed credit N B both in the self with centralized coin mechanism operation and in the built in coin mechanism mode at the end of the cycle all additional residual credits are reset It is therefore rec...

Page 7: ...here are many particularly malodorous garments or items in the cabinet 6 Once the program has been selected the green light turns off and indicates that the cabinet is busy and is running the sanitizi...

Page 8: ...there are few items inside the cabinet or items that are not particularly malodorous Program 2 MEDIUM 35 minutes suitable for a medium load of clothes inside the cabinet Program 3 LONG 40 minutes suit...

Page 9: ...he seat 2 Pull the lever towards you to open Do not force the opening of the machine door during the execution of a sanitizing program always wait for the end of the running program Only when the mess...

Page 10: ...ork properly Check and replace the parts if necessary To reset the machine it is necessary to switch it off and on again using the master switch only after having eliminated the cause of the warning 1...

Page 11: ...programs It is recommended to use a centralized external coin mechanism able to manage 2 bonuses The operation will be as follows 1 You set a basic price in the centralized coin mechanism for example...

Page 12: ...lacing lamps and or ballasts or any material with non genuine parts 18 MECHANICAL RISKS The operator must pay attention to the following situations defined as hazardous from the mechanical point of vi...

Page 13: ...ouch the glass of the lamps with your fingers so as not to leave fingerprints and or fat residues which could compromise their durability fig 2 When you open the door at the end of the program you wil...

Page 14: ...by means of a support Not being a rigid package it is not very resistant to shocks fragile material therefore pay the utmost attention when handling the packaged device do not use it as a stool or as...

Page 15: ...re are damages deriving from a fortuitous event fire short circuit or due to third parties tampering when using the machine for a purpose different than the one specified in this manual when using non...

Page 16: ...ase Exclusion of liability for indirect damage In no case Battistella B G S r l will be held liable for damages including without limitation indirect damage due to loss or loss of earnings business in...

Page 17: ...Gea V 06 16 2018 26 ELECTRICAL DIAGRAM...

Page 18: ...Gea V 06 17 2018...

Reviews: