KEY 

Program selection buttons 

Free/end cycle machine light 

Built-in coin mechanism (accessory) 

Master switch 

Coin mechanism credit display (only 

for the version with built-in coin 
mechanism)  

Door closing knob 

Electronic board/display 

 

 

 

 

2.

 

IMPORTANT

 

 
The  operator  must  carefully  follow  the  recommendations  provided  and  the  warnings 

given below for a better use and preservation of the machine and to avoid injury to 
people or damage to property. 

 

This device must not be used by individuals (including children) with reduced physical, 
sensory  and  mental  capacities,  or  inexperienced,  unless  supervised  by  a  person 

responsible  for  their  safety  and  instructed  with  regard  to  the  use  of  the  equipment. 
Children must be supervised to make sure that they do not play with the device. 

 

To  make  the  hazards  more  obvious,  adhesive  symbols  whose  meaning  is  explained 
below are placed on the critical points of the machine: 

 
 

 
 

3.

 

PACKAGING OPENING

 

 

1.

 

When receiving the machine, make sure that the packaging has not been damaged 
or tampered with. 

2.

 

Proceed  with  unpacking:  take  off  the  box  and  remove  the  supports  that  fix  the 
machine to the pallet; remove the machine from the pallet. 

3.

 

Read carefully the instructions given below (carefully preserve this manual for any 

further reference). 

 

 

4.

 

ELECTRICAL CONNECTION

 

 

Connect the machine to a socket protected with a differential magnetothermal switch 

in  compliance  with  current  regulations  and  with  a  capacity  corresponding  to  the 
characteristics of the sanitizing cabinet. 

 

 

Hot surfaces. Burns hazard.  

Pay attention. 

 

Dangerous electrical voltages. Electric shock hazard. 
Be careful not to come into contact with live parts. 

Cut  off  the  power  supply  of  the  machine  before  removing  the 
protection panels. 

Summary of Contents for GEA

Page 1: ...36028 Rossano Veneto VI ITALY 39 0424 549027 39 0424 549007 www battistellag it info battistellag it This manual is the property of BATTISTELLA B G S r l Any reproduction is prohibited The Company res...

Page 2: ...TOP AND DOOR OPENING 8 11 DOOR OPENING CLOSING 8 12 ADJUSTABLE SHELF 9 13 OZONE BLASTER FAULT 9 14 ABNORMAL SHUTDOWN OF THE PROGRAM NO ELECTRICITY 9 15 CHANGE LANGUAGE 10 16 PLUG CONNECTION ONLY THE M...

Page 3: ...e the product in a manner different than the one specified in this manual 1 MACHINE FEATURES MODEL GEA ELECTRICAL POWER 230 V 50 60 Hz TOTAL INSTALLED POWER 143 W BLOWING MOTOR POWER 73 W OZONE LAMP P...

Page 4: ...not play with the device To make the hazards more obvious adhesive symbols whose meaning is explained below are placed on the critical points of the machine 3 PACKAGING OPENING 1 When receiving the m...

Page 5: ...operation 8 Keep the power supply cord away from hot surfaces and make sure it is not crushed by doors or trampled 9 The machine must be positioned so that there is a distance of no less than 50 cm be...

Page 6: ...shed credit N B both in the self with centralized coin mechanism operation and in the built in coin mechanism mode at the end of the cycle all additional residual credits are reset It is therefore rec...

Page 7: ...here are many particularly malodorous garments or items in the cabinet 6 Once the program has been selected the green light turns off and indicates that the cabinet is busy and is running the sanitizi...

Page 8: ...there are few items inside the cabinet or items that are not particularly malodorous Program 2 MEDIUM 35 minutes suitable for a medium load of clothes inside the cabinet Program 3 LONG 40 minutes suit...

Page 9: ...he seat 2 Pull the lever towards you to open Do not force the opening of the machine door during the execution of a sanitizing program always wait for the end of the running program Only when the mess...

Page 10: ...ork properly Check and replace the parts if necessary To reset the machine it is necessary to switch it off and on again using the master switch only after having eliminated the cause of the warning 1...

Page 11: ...programs It is recommended to use a centralized external coin mechanism able to manage 2 bonuses The operation will be as follows 1 You set a basic price in the centralized coin mechanism for example...

Page 12: ...lacing lamps and or ballasts or any material with non genuine parts 18 MECHANICAL RISKS The operator must pay attention to the following situations defined as hazardous from the mechanical point of vi...

Page 13: ...ouch the glass of the lamps with your fingers so as not to leave fingerprints and or fat residues which could compromise their durability fig 2 When you open the door at the end of the program you wil...

Page 14: ...by means of a support Not being a rigid package it is not very resistant to shocks fragile material therefore pay the utmost attention when handling the packaged device do not use it as a stool or as...

Page 15: ...re are damages deriving from a fortuitous event fire short circuit or due to third parties tampering when using the machine for a purpose different than the one specified in this manual when using non...

Page 16: ...ase Exclusion of liability for indirect damage In no case Battistella B G S r l will be held liable for damages including without limitation indirect damage due to loss or loss of earnings business in...

Page 17: ...Gea V 06 16 2018 26 ELECTRICAL DIAGRAM...

Page 18: ...Gea V 06 17 2018...

Reviews: