PRODUCT DESCRIPTION

 

 

The machine allows the sanitizing and cleaning of garments such as jackets, trousers, 

sweaters,  bathrobes,  towels,  work  clothes,  motorcycle  suits,  sports  helmets,  shoes, 

boots but also textiles such as blankets, cushions , curtains, sofa covers ... etc. 
The ozone produced by the internal generator, allows cleaning and sanitizing thanks 

to its strongly oxidizing natural gas structure. The ozone is able to eliminate bacteria, 
molds,  fungus,  and  insects,  inactivate  viruses  and  oxidize  the  chemical  molecules 

responsible for the most annoying odors that can be eliminated. 

 
The machine is available in three versions: 

 

STANDARD:

  suitable  to  be  installed  in  all  environments  where  it  is  necessary  to 

perform a sanitizing action on shoes, clothes, etc ...; 

SELF  WITH  CENTRALIZED  COIN  MECHANISM  (CC):

  suitable  for  installation  in 

self-service laundries as it can be connected to a centralized coin mechanism. 

The sanitizing program is enabled to reach the established credit; 

SELF  WITH  BUILT-IN  COIN  MECHANISM  (G):

  suitable  for  installation  in  self-

service laundries, where an external centralized coin mechanism is not available. The 
machine has a built-in coin mechanism. 

The sanitizing program is enabled to reach the established credit. 

 
N.B:

 both in the 

self with centralized coin mechanism

 operation and in the 

built-in 

coin mechanism

 mode, at the end of the cycle all additional residual credits are reset. 

It  is  therefore  recommended  to  insert  only  the  credit  needed  to  start  the  chosen 

program. 

 
 

7.

 

PROGRAM PHASES

 

 

The 

program

 or 

sanitizing and cleaning cycle

 consists of three phases: 

 

-

 

Phase 1^:

 ozone is produced to saturate the air inside the cabinet; 

-

 

Phase 2^:

 the ozone-saturated air is circulated by a fan to allow a correct 

distribution and sanitizing action on the items to be sanitized, previously inserted; 

-

 

Phase 3^:

 the air, rich in ozone, is circulated through the blaster. Thanks to this 

system, the ozone decreases and ensures that the indoor air is not harmful to the 

person who opens the door and removes the clothes at the end of the cycle. 
At the same time the germicidal lamp inside, keeps the air 

clean

When  the  machine  door  is  opened,  at  the  end  of  the  sanitizing  and  cleaning 

program, the detection of a slight typical odor of ozone is to be considered normal. 

 

Opening  the  door  when  the  program  has  started  is  forbidden.  During  the 
sanitizing phase, inside the machine there is an ozone level higher than the 

safety  level.  Wait  until  the  program  has  finished  and  the  message 

PROGRAM  COMPLETED  -  OPEN  THE  DOOR

  appears  on  the  display  or  the 

green light is on. 

THE  MACHINE  HAS  A  SAFETY  DEVICE  THAT  PREVENTS  OPENING  THE  DOOR  WHEN 
THE PROGRAM IS RUNNING. 

 

 
 

 

Summary of Contents for GEA

Page 1: ...36028 Rossano Veneto VI ITALY 39 0424 549027 39 0424 549007 www battistellag it info battistellag it This manual is the property of BATTISTELLA B G S r l Any reproduction is prohibited The Company res...

Page 2: ...TOP AND DOOR OPENING 8 11 DOOR OPENING CLOSING 8 12 ADJUSTABLE SHELF 9 13 OZONE BLASTER FAULT 9 14 ABNORMAL SHUTDOWN OF THE PROGRAM NO ELECTRICITY 9 15 CHANGE LANGUAGE 10 16 PLUG CONNECTION ONLY THE M...

Page 3: ...e the product in a manner different than the one specified in this manual 1 MACHINE FEATURES MODEL GEA ELECTRICAL POWER 230 V 50 60 Hz TOTAL INSTALLED POWER 143 W BLOWING MOTOR POWER 73 W OZONE LAMP P...

Page 4: ...not play with the device To make the hazards more obvious adhesive symbols whose meaning is explained below are placed on the critical points of the machine 3 PACKAGING OPENING 1 When receiving the m...

Page 5: ...operation 8 Keep the power supply cord away from hot surfaces and make sure it is not crushed by doors or trampled 9 The machine must be positioned so that there is a distance of no less than 50 cm be...

Page 6: ...shed credit N B both in the self with centralized coin mechanism operation and in the built in coin mechanism mode at the end of the cycle all additional residual credits are reset It is therefore rec...

Page 7: ...here are many particularly malodorous garments or items in the cabinet 6 Once the program has been selected the green light turns off and indicates that the cabinet is busy and is running the sanitizi...

Page 8: ...there are few items inside the cabinet or items that are not particularly malodorous Program 2 MEDIUM 35 minutes suitable for a medium load of clothes inside the cabinet Program 3 LONG 40 minutes suit...

Page 9: ...he seat 2 Pull the lever towards you to open Do not force the opening of the machine door during the execution of a sanitizing program always wait for the end of the running program Only when the mess...

Page 10: ...ork properly Check and replace the parts if necessary To reset the machine it is necessary to switch it off and on again using the master switch only after having eliminated the cause of the warning 1...

Page 11: ...programs It is recommended to use a centralized external coin mechanism able to manage 2 bonuses The operation will be as follows 1 You set a basic price in the centralized coin mechanism for example...

Page 12: ...lacing lamps and or ballasts or any material with non genuine parts 18 MECHANICAL RISKS The operator must pay attention to the following situations defined as hazardous from the mechanical point of vi...

Page 13: ...ouch the glass of the lamps with your fingers so as not to leave fingerprints and or fat residues which could compromise their durability fig 2 When you open the door at the end of the program you wil...

Page 14: ...by means of a support Not being a rigid package it is not very resistant to shocks fragile material therefore pay the utmost attention when handling the packaged device do not use it as a stool or as...

Page 15: ...re are damages deriving from a fortuitous event fire short circuit or due to third parties tampering when using the machine for a purpose different than the one specified in this manual when using non...

Page 16: ...ase Exclusion of liability for indirect damage In no case Battistella B G S r l will be held liable for damages including without limitation indirect damage due to loss or loss of earnings business in...

Page 17: ...Gea V 06 16 2018 26 ELECTRICAL DIAGRAM...

Page 18: ...Gea V 06 17 2018...

Reviews: