Transport  the  packed  machine  close  to  the  installation  point  and  proceed  with 

unpacking. The appliance must not be transported manually by people, but by means 
of forklift trucks. 

It  is  recommended  not  to  place  the  machine  too  close  to  the  walls  and  other 
machines; position it far from electric and electronic parts and cable tray in order to 

guarantee the operator an easy use and perfect maintenance. 

 
 

23.

 

STORAGE

 

 

If  necessary,  store  the  machine  still  packed  in  a  suitable  place,  protected  and  not 
subject to bad weather. 

 

 
24.

 

WARRANTY TERMS

 

 

The manufacturer's warranty becomes void: 

 

 

in the event of repairs carried out by unauthorized personnel or service centers; 

 

total or partial failure to follow the instructions contained in this manual;  

 

for poor storage, lack of maintenance/cleaning or incorrect assembly; 

 

when there are damages caused by the customer; 

 

when  there  are  failures  or  damages  that  do  not  derive  from  a  manufacturing 

defect; 

 

when  there  are  damages  deriving  from  a  fortuitous  event  (fire,  short  circuit)  or 
due to third parties (tampering); 

 

when  using  the  machine  for  a  purpose  different  than  the  one  specified  in  this 
manual; 

 

when  using  non-genuine  spare  parts  or  accessories,  modified  or  not  suitable  for 

the appliance. 

 

 

25.

 

DISPOSAL

 

 

According  to  the  directive  2012/19/UE  on  waste  of  electrical  and 

electronic equipment, do not treat this product as urban waste. 
This appliance is marked according to the directive 2011/65/UE regarding 

restriction  of  use  of  specific  dangerous  substances  in  electrical  and 

electronic equipment.  
This symbol on the product or on its packaging indicates that this product 

must not be treated as urban waste. Instead it shall be handed over to a 
recycling center for the recycling of electrical and electronic equipment. 

Ensuring  this  product  is  disposed  of  correctly  will  help  prevent  potential  negative 

consequences for the environment and human health which could otherwise be caused 
by  inappropriate  waste  handling  of  this  product.  The  recycling  of  materials  will  help 

preserve natural resources. 
The abusive disposal of the product by the user may lead to administrative sanctions. 

 
 

 

 

Summary of Contents for GEA

Page 1: ...36028 Rossano Veneto VI ITALY 39 0424 549027 39 0424 549007 www battistellag it info battistellag it This manual is the property of BATTISTELLA B G S r l Any reproduction is prohibited The Company res...

Page 2: ...TOP AND DOOR OPENING 8 11 DOOR OPENING CLOSING 8 12 ADJUSTABLE SHELF 9 13 OZONE BLASTER FAULT 9 14 ABNORMAL SHUTDOWN OF THE PROGRAM NO ELECTRICITY 9 15 CHANGE LANGUAGE 10 16 PLUG CONNECTION ONLY THE M...

Page 3: ...e the product in a manner different than the one specified in this manual 1 MACHINE FEATURES MODEL GEA ELECTRICAL POWER 230 V 50 60 Hz TOTAL INSTALLED POWER 143 W BLOWING MOTOR POWER 73 W OZONE LAMP P...

Page 4: ...not play with the device To make the hazards more obvious adhesive symbols whose meaning is explained below are placed on the critical points of the machine 3 PACKAGING OPENING 1 When receiving the m...

Page 5: ...operation 8 Keep the power supply cord away from hot surfaces and make sure it is not crushed by doors or trampled 9 The machine must be positioned so that there is a distance of no less than 50 cm be...

Page 6: ...shed credit N B both in the self with centralized coin mechanism operation and in the built in coin mechanism mode at the end of the cycle all additional residual credits are reset It is therefore rec...

Page 7: ...here are many particularly malodorous garments or items in the cabinet 6 Once the program has been selected the green light turns off and indicates that the cabinet is busy and is running the sanitizi...

Page 8: ...there are few items inside the cabinet or items that are not particularly malodorous Program 2 MEDIUM 35 minutes suitable for a medium load of clothes inside the cabinet Program 3 LONG 40 minutes suit...

Page 9: ...he seat 2 Pull the lever towards you to open Do not force the opening of the machine door during the execution of a sanitizing program always wait for the end of the running program Only when the mess...

Page 10: ...ork properly Check and replace the parts if necessary To reset the machine it is necessary to switch it off and on again using the master switch only after having eliminated the cause of the warning 1...

Page 11: ...programs It is recommended to use a centralized external coin mechanism able to manage 2 bonuses The operation will be as follows 1 You set a basic price in the centralized coin mechanism for example...

Page 12: ...lacing lamps and or ballasts or any material with non genuine parts 18 MECHANICAL RISKS The operator must pay attention to the following situations defined as hazardous from the mechanical point of vi...

Page 13: ...ouch the glass of the lamps with your fingers so as not to leave fingerprints and or fat residues which could compromise their durability fig 2 When you open the door at the end of the program you wil...

Page 14: ...by means of a support Not being a rigid package it is not very resistant to shocks fragile material therefore pay the utmost attention when handling the packaged device do not use it as a stool or as...

Page 15: ...re are damages deriving from a fortuitous event fire short circuit or due to third parties tampering when using the machine for a purpose different than the one specified in this manual when using non...

Page 16: ...ase Exclusion of liability for indirect damage In no case Battistella B G S r l will be held liable for damages including without limitation indirect damage due to loss or loss of earnings business in...

Page 17: ...Gea V 06 16 2018 26 ELECTRICAL DIAGRAM...

Page 18: ...Gea V 06 17 2018...

Reviews: