Giove
11
2020
ATTENTION:
never connect the appliance with the safety
cap removed.
During water refilling be careful not to spill water outside
the machine. If this happens, dry immediately to avoid
electrical hazards.
13.
SANITIZER LIQUID REFILL
Periodically check the level of the sanitizer liquid in the tank.
When the liquid falls below the "MIN" mark, refill the tank
immediately, but do not go beyond the "MAX" mark.
To fill the tank, simply lift the lid (fig. 6).
Perform the operation with the machine disconnected from the
mains.
14.
BOILER DISCHARGE
Drain the boiler periodically. Carry out the operation with the
machine turned off and cold and with the plug disconnected
from the mains. Wait at least 1 hour after switching off. During
this procedure, wear work gloves to avoid possible burns.
Remove the valve cap and open the boiler drain cock (fig. 7),
wait for all the water to come out and finally close the boiler
drain cock. It may happen that the drain cock gets clogged: in
this case, take an iron wire with a diameter of 3-4 mm or
similar and introduce it into the duct to unclog it.
Fig. 5
Fig. 6
WATER
DISCHARGE
TAP
Fig. 7