7.

 

CONNECTION AND STARTING

 

 

1.

 

Connect the rubber hose to the hose-holder indicated as WATER INLET placed on 

the  Plutone 

(fig.  1)

  and  turn  the  water  tap on. For  Plutone  equipped  with  water 

tank, you just have to fill it and connect the machine to the mains supply. 

N.B.: 

make sure there is always water inside the water tank.  

2.

 

Connect the power supply cable to a protected outlet with earth protector switch , 

with observance of the law in force and a voltage suitable to PLUTONE.  

3.

 

Turn  on  the  main  switch 

(fig.  1)

  and  select  the  functions  which  are  to  be 

activated. 

N.B.:

 the settings of the electronic card are memorized every time the 

main switch is turned off. Once the machine is turned on again, it will start with the 

settings memorized before the machine was turned off (e.g. if the boiler was on, it 

will  be  on  upon  switching  on  the  machine). 

  WARNING: 

the  electronic  card 

automatically  performs  a  check  of  the  software  installed.  This  is  why  it  takes  2 

seconds for the machine to turn on.  
If an error or fault is found, the “safety” device blocks the electronic card and does 

not  allow  normal  functioning.  “

SOFTWARE  ERROR” 

will  be  displayed.  Contact  the 

Authorized Service Centre to update the software. 

4.

 

Wait until  the  boiler  light is  fixed  (not  intermittent)  and  the  manometer  shows  4 

Bar.  Seize  the  iron  by  the  cork  handle  and  press  the  micro-switch  3  or  4  times 

(fig. 3)

, so that steam comes out: this operation must be carried out in order to 

heat up the  hoses  which take  steam to  the  iron. This  prevents  also  the  falling  of 
small drops of water on garments (iron must always be held in such a way as not 

to harm operator, that is with iron always pointed downwards). 

5.

 

To  adjust  the  steam  flux  you  must  work  on  the  steam  adjustment  tap 

(fig.  1: 

solenoid valve)

6.

 

After  this,  PLUTONE  is  ready  for  use.  During  ironing  the  icon  of  the  boiler  may  

remain intermittent (card is raising steam) or fixed (optimum pressure), indicating 

that PLUTONE is working properly.  

N.B.: 

during ironing the warning light  

 will switch on and “WATER PUMPING” 

will be displayed. This means that the card is automatically pumping water into the 

boiler. 

N.B.: 

in  the  event  the  pump  should  remain  without  water  for  a  long  time,  the 

“pump saving” device will be activated and the pump will not work. This is shown  

by  the  icon   

  and  the  warning  “PUMP  BLOCKED”  will  be  displayed.  An 

intermittent acoustic alarm is also audible.  

If this device is activated, check that there is enough pressure in the water system 
or that there is water inside the water tank. If one of the previous is the cause of 

the  blockage,  turn  the  card  off  and  on  by  using  the  main  switch.  If  the  problem 
remains, do not insist and contact the manufacturer or Authorized Service Centre.  

 

FOR PLUTONE CONNECTED TO THE WATER SYSTEM: 

For PLUTONE connected to the water system, verify that the water pressure is not 

more than 2,5 Bar. If so, the pump will be blocked and this will prevent the water 
from entering the boiler. 

 
 

 

 
 

 

 

Summary of Contents for PLUTONE 2009

Page 1: ...LLED POWER W 5648 W 5970 POWER OF IRON 1 W 800 W 800 POWER OF IRON 2 W 800 W 800 BOILER POWER W 4000 W 4000 PUMP POWER W 48 Hp 0 5 BOILER CAPACITY 5 L 5 L IRONING ENDURANCE CONTINUOUS CONTINUOUS OPERA...

Page 2: ...protected electrical outlet suitable to PLUTONE power 3 OPENING OF PACKAGE 1 Open the box containing PLUTONE from the upper side marked as ALTO take out the instructions handbook and read it carefull...

Page 3: ...NTERMITTENT LIGHT indicates that the boiler is on and that the water is being heated to obtain steam Indicates that iron 1 is functioning Indicates that iron 2 is functioning Indicates that the pump i...

Page 4: ...4 times fig 3 so that steam comes out this operation must be carried out in order to heat up the hoses which take steam to the iron This prevents also the falling of small drops of water on garments...

Page 5: ...RESET OF WARNINGS Ok FILTER Zeroing of hours SET Reset Ok To exit Esc COVER PROBE Reset is necessary in order to delete the warnings from the display once maintenance has been done Example WARNING PRO...

Page 6: ...nly when the boiler is cold and the plug is disconnected from the mains 3 Never leave hot iron on the ironing board 4 Connect PLUTONE to a suitable and protected outlet 5 After ironing is over switch...

Page 7: ...water fig 3 9 loss of water from PLUTONE base fig 1 10 loss of steam from inner part of PLUTONE 12 MECHANICAL RISKS The following situations are considered dangerous for the operator 1 using PLUTONE f...

Page 8: ...off and are cold fig 2 4 cleaning of the water inlet filter fig 4 and cleaning of the foot valve filter PLUTONE with water tank fig 1 15 CLEANING OF WATER FILTER The cleaning of the filter is to be do...

Page 9: ...ERIODICAL MAINTENANCE TO BE CARRIED OUT EXCLUSIVELY BY AUTHORIZED SERVICE CENTRES QUALIFIED TECHNICIANS OR BY THE MANUFACTURER Compulsory maintenance is signalled by the icon GENERAL MAINTENANCE will...

Page 10: ...osal and recycling of the machine s components assures protection of the natural environment Every product manufactured by BATTISTELLA B G S r l is subject to the following limitations Battistella B G...

Reviews:

Related manuals for PLUTONE 2009