17.
WORKING CYCLE
After having started the boiler
(when the boiler is under pressure the “steam” icon will
turn off), carried out all the adjustments and chosen the program, ZEUS is ready for
use.
To start the automatic cycle, just insert the sleeves into the clamps. ZEUS will
automatically tighten them. Now press the pedal
(fig. 1)
. This way the arms get in
traction and the steam cycle is activated, then the air-steam cycle and, eventually,
the hot air cycle. The various phases and timings are shown on the display. Once the
working cycle has finished, the clamps open and the arms close down; the operator
can start another cycle.
N.B. The working cycle does not start if the temperature of the super-heater
is below 120°C and/or if both the
clamps have not closed themselves
correctly. If the clamps are not necessary, follow instruction as per chapter
“
Deactivation and activation of arms and clamps
”
.
Note:
1. it is possible to interrupt the working cycle anytime by pressing the pedal;
2. each time you change the type of fabric to iron, and especially when changing from
heavy fabrics to delicate ones, just repeat the settings at points
13
and
14
;
3. it is not possible to change the timings of the various phases during the working cycle.
18.
DEACTIVATION AND ACTIVATION OF ARMS AND CLAMPS
Whenever y
ou don’t need arms and
clamps, you can deactivate them and go on with
the normal ironing cycle.
In order to deactivate the clamps just
follow these points:
1.
Press the “
clamps
deactivation”
key (the led will turn on)
2.
Turn the air closing valve to
position
OFF
(no clamps)
(fig. 6).
In order to reactivate the clamps just
follow these points:
1.
Press the “
clamps
deactivation”
key (the led will turn off)
2.
Turn the air closing valve to
position
ON
(with clamps)
(fig.
6).
WARNING! For a good functioning of the ironing cycle remember to press the
key and turn the valve.
ESC
ADJUSTME NT
OF GENERAL
PRE SSURE
LUBRICATOR
MANOMETE R
AIR INLET
"CLAMPS DEACTIVATION"
KEY
ON
OFF
(WITHOUT CLAMPS)
(WITH CLAMPS)
AIR CLOSING
VALVE