1. Contactor  

2. Sleeve stretch. arm 

3. Left clamps 

4. Right clamps 

5. Pump 

6. Blowing motor 

7. Steam solenoid valve 

8. Photocell 

9. Super-heater resistance 

 
 

28.

 

 SUBSTITUTION OF POWER CURRENT FUSES 

 

The  power  current  fuses  protect  the  whole  machine  and  are 
situated near the electronic card.  If the fuses of the electronic 

card  have  been  checked  and  are  not  damaged,  check  the 

power current fuses and replace them if necessary. 
To gain access to the fuses the main switch must be on pos. 

“0”

 and the four screws are to be unscrewed from the panel. 

N.B.:  SUBSTITUTE  FUSES  WITH  INTERCHANGEABLE  ONES 

AND WITH THE SAME PERFORMANCE. 

 

 
29.

 

 COMPULSORY AND PERIODICAL MAINTENANCE  

 

(TO BE CARRIED OUT EXCLUSIVELY BY AUTHORIZED SERVICE CENTRES, QUALIFIED 
TECHNICIANS OR BY THE MANUFACTURER.)  

 

Compulsory  maintenance  is  signalled  by  icon 

.    Contact  ONLY  the  reseller, 

Authorized  Service  Centres  or  the  manufacturer  in  order  to  carry  out  the  required 
maintenance/inspections.  Once  maintenance  has  been  done  the  warning  will  be 

removed. 

230V 2A

1

2

230V 4A

3

230V 5A

4

230V 5A

5

230V 4A

6

230V 4A

7

230V 4A

9

230V 15A

8

230V 315mA

 

Fig. 9 

Power current fuses

400V - 32A

 

Summary of Contents for PNEUMATIC ZEUS/A

Page 1: ...ATIC ZEUS A mod 2009 POWER SUPPLY V 400 NEUTRAL TOTAL INSTALLED POWER W 11850 BOILER POWER W 9000 VACUUM BLOWING MOTOR POWER HP 1 75 HZ 50 PUMP POWER HP 0 8 HZ 50 BOILER CAPACITY L 10 IRONING ENDURANC...

Page 2: ...s in stand by mode red led on This mode allows access to the SET menu in order to set functions such as language periodical maintenance warnings etc see point 6 Electronic card in stand by mode If mai...

Page 3: ...m phase timing increase decrease keys Timing may be set from 0 to 99 seconds Air steam phase timing increase decrease keys Timing may be set from 0 to 99 seconds RESET Air phase timing increase decrea...

Page 4: ...time Check that water comes out of the pipe connected to the water supply Turn off the main switch wait for 5 seconds and turn the machine on again If the problem reoccurs contact Authorized Service...

Page 5: ...supply cable to a grounded outlet with observance of the law in force and a voltage suitable to ZEUS 4 Connect the compressed air tube to the pressure adapter and adjust it to a maximum pressure of 6...

Page 6: ...ed Manufacturer authorized access only WARNING AFTER 10 ATTEMPTS TO ACCESS THE MAINTENANCE OR MANUFACTURER MENU WITHOUT TYPING IN THE PASSWORD AND OR BY TYPING THE WRONG PASSWORD THE SET MENU WILL BE...

Page 7: ...by grasping the handle and pulling the racket with one s thumb fig 3 In addition by turning the handle clockwise or anticlockwise you can adjust the pressure exerted by the paddle on the garment prev...

Page 8: ...ps too much a high pressure might cause hand injuries if accidentally pressed by the clamps Should it occur push immediately on the opening button fig 2 15 ADJUSTMENT OF OPENING AND CLOSING SPEED OF A...

Page 9: ...he values stored by the manufacturer will be set According to the ironing program chosen the suggested air adjustment will be displayed Fig 1 Example KINTTED LADIES DRESS air adj 1 N B the setting of...

Page 10: ...of arms and clamps Note 1 it is possible to interrupt the working cycle anytime by pressing the pedal 2 each time you change the type of fabric to iron and especially when changing from heavy fabrics...

Page 11: ...or the operator 1 damaging of electrical cables of the iron 2 the earth protector switch is activated when switching on the main switch 3 using ZEUS during thunderstorms 4 using ZEUS without proper pr...

Page 12: ...3 For six monthly cleaning of ZEUS follow these instructions open the side and back panels clean the inner part with compressed air with special care to the ventilator fan of the blowing motor 4 Chec...

Page 13: ...he power current fuses see SUBSTITUTION OF POWER CURRENT FUSES To restart the machine do as follows set the main switch on position 0 unscrew the 4 screws of the panel find the motor protector and res...

Page 14: ...uses the main switch must be on pos 0 and the four screws are to be unscrewed from the panel N B SUBSTITUTE FUSES WITH INTERCHANGEABLE ONES AND WITH THE SAME PERFORMANCE 29 COMPULSORY AND PERIODICAL M...

Page 15: ...disposal and recycling of the machine s components assures protection of the natural environment Every product manufactured by BATTISTELLA B G S r l is subject to following limitations Battistella B...

Reviews: