background image

Saturno Max - Saturno Max/S 

2005 

-

 

Make  sure  the  water  filter  is  not  obstructed  because  of  dirt  waste  (fig. 

4A). 

 
The  lamps  of  heating  element  1  and  2  are  always  on,  but  the  boiler  does  not  reach 
steam operating pressure: 
-

 

Make  sure  the  main  switch  for  power  supply  is  on.  If  the  problem 

persists: 

-

 

disconnect  the  plug  and  make  sure  the  voltage  is  on  and  the  power 

supply cable is connected to the steam generator correctly; 

-

 

check the internal fuses. 

 
 
6.

 

LITTLE MAINTENANCES 

 
Empty  the  boiler  periodically  –  with  the  machine  switched  off  and  a  pressure  of  0,5 
BAR.  For  carrying  out  this  operation,  turn  the  exhaust  tap  slowly:  we  advise  you  to 
wear gauntlets against possible burns. 
 
 
7.

 

ORDINARY MAINTENANCE 

 
Let  a  specialized  technician  have  a  general  check  at  least  twice  per  year.  SATURNO 
MAX  was  projected  to  work  maximum  8  hrs.  per  day,  5  days  a  week.  In  these 
conditions, the machine is expected to function for 7 years. 
 
It is recommended: 
 
1.

 

to check the efficiency of the security devices (manometer, pressure switches, level 
regulator); 

2.

 

to  test  the  functioning  of  the  security  valves  every  1000  hrs.  of  operation  or 
maximum 6 months (fig. 4B); 

3.

 

to  dismantle  the  copper  tubes  of  the  manometer  and  of  the  pressure  switch  and 
clean them from deposits and scales; 

4.

 

to  clean  the  boiler  and  the  elements  of  the  resistances  from  limestone  deposits, 
check that the rubber tubes of the pump and of the boiler are not obstructed; 

5.

 

to dismantle the level regulator and clean it from limestone scales, test the capacity 
of the joints, clean the filter and the valve of water inlet. 

 

SECURITY
VALVE

FILTER

 

Summary of Contents for SATURNO MAX L.24

Page 1: ...51 BATTISTELLA B G S r l Via Bessica 219 36028 Rossano Veneto VI ITALY 39 0424 549027 39 0424 549007 www battistellag it info battistellag it This manual is property of BATTISTELLA B G S r l We reserv...

Page 2: ...Y 400 V NEUTRAL 50Hz 400 V NEUTRAL 50Hz TOTAL INSTALLED POWER 18 5 or 24 5 kW 36 5 or 48 5 kW BOILER POWER 18 or 24 kW 36 or 48 kW PUMP POWER 0 7 Hp 0 7 Hp BOILER CAPACITY 24 L 51 L IRONING ENDURANCE...

Page 3: ...inlet 8 13 mm which must be fixed tightly with 2 hose clamps N B before inserting the rubber tube into SATURNO MAX hose holder exhaust a few litres of water in order to clean the conduit 2 an electric...

Page 4: ...e tank must be equipped with an automatic temperature control device for water discharge and cold water input 2 connect the power supply cable to a protected outlet with earth protector switch with ob...

Page 5: ...ANCE Let a specialized technician have a general check at least twice per year SATURNO MAX was projected to work maximum 8 hrs per day 5 days a week In these conditions the machine is expected to func...

Page 6: ...e does not increase or it takes much time to do so Check the resistances and their remote control switches Some steam gets out of the security valve and the boiler overcomes the definite pressure Chec...

Page 7: ...sibly controlled thanks to manometer 12 THERMAL RISKS The following situations are considered dangerous for the operator 1 touching the external security valve when the machine is on 2 emptying the bo...

Page 8: ...ate waste handling of this product The recycling of materials will help to conserve natural resources The abusive disposal of the product by the user may lead administrative sanctions Every product ma...

Reviews: