Saturno Max - Saturno Max/S
4
2005
-
Make sure the water filter is not obstructed because of dirt waste (fig.
4A).
The lamps of heating element 1 and 2 are always on, but the boiler does not reach
steam operating pressure:
-
Make sure the main switch for power supply is on. If the problem
persists:
-
disconnect the plug and make sure the voltage is on and the power
supply cable is connected to the steam generator correctly;
-
check the internal fuses.
6.
LITTLE MAINTENANCES
Empty the boiler periodically – with the machine switched off and a pressure of 0,5
BAR. For carrying out this operation, turn the exhaust tap slowly: we advise you to
wear gauntlets against possible burns.
7.
ORDINARY MAINTENANCE
Let a specialized technician have a general check at least twice per year. SATURNO
MAX was projected to work maximum 8 hrs. per day, 5 days a week. In these
conditions, the machine is expected to function for 7 years.
It is recommended:
1.
to check the efficiency of the security devices (manometer, pressure switches, level
regulator);
2.
to test the functioning of the security valves every 1000 hrs. of operation or
maximum 6 months (fig. 4B);
3.
to dismantle the copper tubes of the manometer and of the pressure switch and
clean them from deposits and scales;
4.
to clean the boiler and the elements of the resistances from limestone deposits,
check that the rubber tubes of the pump and of the boiler are not obstructed;
5.
to dismantle the level regulator and clean it from limestone scales, test the capacity
of the joints, clean the filter and the valve of water inlet.
SECURITY
VALVE
FILTER