8.
POSSIBLE FAILURES
The manometer marks pressure in the boiler even if the machine is off and cold:
-
Check the level control and the water inlet valve.
The pump lamp is on and the pump is activated, but the boiler does not get water:
-
Make sure the tube for water inlet in the boiler is not obstructed by
limestone, check the water inlet filter (fig. 4A); if the generator takes
water from the tank for condensate recovery, make sure the water is not
too hot (it should never go over 40° C).
The pump keeps on turning, its lamp is on and the cold boiler increases its pressure:
-
Check the level control (its sphere might be perforated).
The resistance lamp is on, but the pressure does not increase or it takes much time to do so:
-
Check the resistances and their remote control switches.
Some steam gets out of the security valve and the boiler overcomes the definite pressure:
-
Check the pressure switches.
ATTENTION: before any intervention on the machine, remember to disconnect the
plug. Before working on the steam system, turn off the boiler and reset the pressure.
9.
COMPULSORY
1.
Connect SATURNO MAX to a suitable protected outlet;
2.
after operation is over, switch the SATURNO MAX off and close the water;
remember to open it before switching on the machine again;
3.
always keep children away from SATURNO MAX, both when it is on and off;
Fig. 4A
Fig. 4B
OPTIONAL
–
Condense water recovering tank assembled
to the steam generator
CONDENSATE
RETURN
CONDENSATE
RETURN
3/8"
1/2"
1/2"
BOILER
EXHAUST TAP
STEAM OUTPUT
VALVE
TANK EXHAUST
TAP
Water entrance
from the city pipe
Fig. 5