background image

SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD

Website: www.baudcom.com.cn

Tel: +86 21 37709251

Email: info@baudcom.com.cn

BD-PON-J310G

XGPON/10GEPON Power Meter

User Manual

Summary of Contents for BD-PON-J310G

Page 1: ...SHANGHAI BAUDCOM COMMUNICATION DEVICE CO LTD Website www baudcom com cn Tel 86 21 37709251 Email info baudcom com cn BD PON J310G XGPON 10GEPON Power Meter User Manual...

Page 2: ...Contents 1 Product Introduction 1 2 Technical Specifications 1 3 Function Description 2 4 Operation Instruction 2 4 1 Power ON OFF 3 4 2 Test PON power meter 3 4 3 Edit PON Threshold 3 4 4 Record 4 4...

Page 3: ...G E PON Module Wavelength Wavelength Wavelength Wavelength Range dBm Range dBm Range dBm Range dBm Spectral band pas s Spectral band pass Spectral band pass Spectral band pass Isolation Isolation Iso...

Page 4: ...SHANGHAI BAUDCOM COMMUNICATION DEVICE CO LTD 2 Working time Working time 20H standby time 60H Size L W H 192mm 102mm 50mm Weight 420g Function Description Appearance...

Page 5: ...appearance of the product Ensure the correct installation of the battery 2 Press the key until the screen is light The backlight of product will be dim if there is no operation in 60 seconds You can s...

Page 6: ...f the power within the measuring ranger of instrument the screen can show the correct measurements If you want to save the data Please press Confirm key 4 2 2 In this interface you can update referenc...

Page 7: ...is always the number of the last record it also means the used RAM As shown in Figure4 4 Settings The Interface of instrument setting can set the instrument time the backlight brightness waiting time...

Page 8: ...me time 1 Open the PON power meter first of all click connect connect PON power meter to the computer Click English to set the language of the operation interface to be English 2 choose Upload Data cl...

Page 9: ...10dBm type 10dBm in the text box of input standard power and click Calibration tab then finished the calibration operation at 1310nm wavelength See figure 5 3 5 3 Maintenance 1 The tester should work...

Page 10: ...ace Reconnect the fiber Quality Insurance Caution Repair it in the field is NOT recommended 1 We warrants that PON Optical Power Meter will be free from defects in material and workmanship for a perio...

Page 11: ...SHANGHAI BAUDCOM COMMUNICATION DEVICE CO LTD 9 high voltage humidity and etc we will charge depend on the actual failure rating Order Information XGPON 10GEPON Power Meter...

Reviews: