SHANGHAI BAUDCOM COMMUNICATION DEVICE CO.,LTD
Website: www.baudcom.com.cn Tel: +86 21 37709251 Email: info@baudcom.com.cn
(
7
)
Press the down button to display the temperature of pump 2
:
(
8
)
Press the down button to display the operating current of pump 3
:
(
9
)
Press the down button to display the temperature of pump tube 3:
(
10
)
Press the down button to display input optical power:
(
11
)
Press the down button to display output optical power:
(
12
)
Press the down button to display working status:
In this screen, press the Menu button to display "ON" opens AGC function . If a high-power pump
is damage, the other pump will increase the pumping power automatically to maintain the stability
of output power. Press the Return key to display "OFF", this function is off.
(
13
)
Press the down button to display the status of the pump:
In this screen, press the Menu button to display "ON" pump working.
Press the Return key to display "OFF" pumped off.
Indicator
Pump1
:
Pump 1 indicator off is normal, pump 1 flashing is alarming.
Pump2
:
Pump 2 indicator off is normal, pump 2 flashing is alarming.
Alarm
:
Alarm Indicator: input and output light turns red when alarming.
LD2 COOLER **.*
℃
LD3 Current *.* A
LD3 COOLER **.*
℃
Input *.**mW *.*dBm
OUTPUT ***MW **.*DBM
AGC Conerol ***
PUMP CONTROL **