ImVT 120 II Mini Verticus
Page 24
1st Edition, Rev. 0 Chg. 10
5. Check the pressure valve function and stroke by lifting the valve parts.
6. Ensure the stud (2) is unscrewed, then screw in the pressure plug (3)and tighten.
7. Screw the stud (2) in firmly, fit a new gasket and secure it with the cap nut (1).
8. Replace the valve head (7) on the cylinder and secure it with the screws (8).
9. Reconnect the intake and pressure lines.
3.1.9.5
IK120 II 3rd Stage Valves
3.1.9.5.1
Removing the Valves of the 3rd Stage
1. Remove the intake and pressure lines from the valve head (2).
2. Remove the cap nut (8) and loosen stud (6) three or four turns.
3. Remove the screws (9) holding the valve head onto the cylinder and take off valve head cover (5).
4. Remove the 3rd stage pressure valve by putting two screwdrivers into the removal groove of the
pressure valve body. See Figure 3-17. It may be necessary to loosen the valve body first by turning
it with a 13 mm wrench used on the flat surfaces.
Figure 3-16
IK120 II 3rd Stage Valves
1. Intake Valve
2. Valve Head
3. O-ring
4. Pressure Valve
5. Valve Head Cover
6. Stud
7. Gasket
8. Cap Nut
9. Allen Screw
10. Washer
1
2
3
4
5
6
7
8
9
10