Page 13
For technical questions, please call 1-888-866-5797.
Item 58152
SA
FE
TY
OP
ERA
TI
O
N
MAINT
ENANC
E
SE
TUP
Troubleshooting
Problem
Possible Causes
Likely Solutions
Tool will not start.
1. Battery Pack not properly
connected.
2. Battery Pack not properly
charged.
3. Battery Pack burnt-out.
4. Internal damage or wear.
1. Remove Battery Pack, make sure there are no
obstructions, reinsert the Battery Pack according
to its shape (it should only fit one way), and press
firmly until the Battery Pack locks in place.
2. Make sure Charger is connected and
operating properly. Give enough time for
Battery Pack to recharge properly.
3. Dispose of old Battery Pack
properly or recycle. Replace Battery Pack.
4. Have technician service tool.
Mixing Paddle
wobbles.
Chuck loose.
Tighten the Chuck.
Unsatisfactory
mixing results.
Tool speed too fast or too slow.
Check with material manufacturer’s recommendations
for proper mixing speed. Then adjust Gear Switch
and/or Speed Dial to proper tool mixing speed.
Tool operates slowly. Material too thick.
Thin out material.
Excessive noise
or rattling.
Internal damage or wear.
Have technician service tool.
Overheating.
1. Forcing tool to work too fast.
2. Blocked motor housing vents.
1. Allow tool to work at its own rate.
2. Wear ANSI-approved safety goggles and
NIOSH-approved dust mask/respirator while
blowing dust out of motor using compressed air.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect Battery Pack and Charger power supply before service.