Operating instruction manual - B-TIMER
4
Reset
The filter capacity may only be reset after the
cartridge has been replaced!
To reset the filter capacity or the A, B and C service intervals,
hold the
button down for more than 5 seconds when the
respective display has been activated (Figure 11).
Setup
To navigate to the setup menu of the various functions of the
B-TIMER
, hold down the
and
buttons simultaneously for
more than 5 seconds when the cartridge number is being
displayed (Figure 10). The filter icon starts blinking (Figure 12),
which indicates the setup mode.
The applicable filter-cartridge no. is set under
setup A
. To
change the article number, hold down the
button for
3 seconds, after which the number starts blinking. Use the
button to set the desired number. Use the
button to accept
the number in question.
Article numbers beginning with 999 must be
set in a special manner.
Hold down the
button for 3 seconds, and then enter 999000
with
. The last 0 starts blinking. Appoint the corresponding
digit with
and accept it with
. When the 2nd zero starts
blinking, appoint the digit as described above, and carry out the
same procedure for the 3rd digit.
When the
button is pressed, the display switches over to
setup B
(setting of the delivery quantity). The filter icon starts
blinking (Figure 13). The delivery quantity (in l/min.) can be
found in the compressor’s instruction manual. To change the
configuration, hold down the
button for 3 seconds, after
which the 1st digit starts blinking. Use the
button to set the
desired number. Use the
button to accept the number in
question and repeat the same procedure until all three digits
have been set correctly.
When the
button is pressed again, the display switches over
to
setup C
(setting of operating pressure). The filter icon starts
blinking (Figure 14).
To change the operating pressure, hold down the
button for
more than 3 seconds. Press the
button to enter the new
operating pressure. (Options: 200 bar, 300 bar or 200/300 bar).
Press the
button to confirm the new setup.
The filter capacity must be reset after the
setup preferences have been entered and a
new filter cartridge has been inserted. Refer
to the
‘Reset’
section.
When the
button is pressed again, the display switches over
to the
setup menu for the operating hours
. Press the
button for 2 seconds, after which the last digit starts blinking.
Use the
button to appoint the desired digit and press the
button. Repeat this procedure until all the digits have been
entered. Repeated actuation of the
button leads the system
back to the main menu. Pressing the
and
buttons (for
2 seconds) makes it possible to repeat the setup procedure.
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14