Operating instruction manual - B-TIMER

4

Reset

The filter capacity may only be reset after the
cartridge has been replaced!

To reset the filter capacity or the A, B and C service intervals,
hold the



button down for more than 5 seconds when the

respective display has been activated (Figure 11).

Setup

To navigate to the setup menu of the various functions of the

B-TIMER

, hold down the

and



buttons simultaneously for

more than 5 seconds when the cartridge number is being
displayed (Figure 10). The filter icon starts blinking (Figure 12),
which indicates the setup mode.
The applicable filter-cartridge no. is set under

setup A

. To

change the article number, hold down the



button for

3 seconds, after which the number starts blinking. Use the

button to set the desired number. Use the



button to accept

the number in question.

Article numbers beginning with 999 must be
set in a special manner.

Hold down the



button for 3 seconds, and then enter 999000

with

. The last 0 starts blinking. Appoint the corresponding

digit with

and accept it with

. When the 2nd zero starts

blinking, appoint the digit as described above, and carry out the
same procedure for the 3rd digit.
When the

button is pressed, the display switches over to

setup B

(setting of the delivery quantity). The filter icon starts

blinking (Figure 13). The delivery quantity (in l/min.) can be
found in the compressor’s instruction manual. To change the
configuration, hold down the



button for 3 seconds, after

which the 1st digit starts blinking. Use the

button to set the

desired number. Use the



button to accept the number in

question and repeat the same procedure until all three digits
have been set correctly.
When the

button is pressed again, the display switches over

to

setup C

(setting of operating pressure). The filter icon starts

blinking (Figure 14).
To change the operating pressure, hold down the



button for

more than 3 seconds. Press the

button to enter the new

operating pressure. (Options: 200 bar, 300 bar or 200/300 bar).
Press the

button to confirm the new setup.

The filter capacity must be reset after the
setup preferences have been entered and a
new filter cartridge has been inserted. Refer
to the

‘Reset’

section.

When the

button is pressed again, the display switches over

to the

setup menu for the operating hours

. Press the



button for 2 seconds, after which the last digit starts blinking.
Use the

button to appoint the desired digit and press the



button. Repeat this procedure until all the digits have been

entered. Repeated actuation of the

button leads the system

back to the main menu. Pressing the

and



buttons (for

2 seconds) makes it possible to repeat the setup procedure.

Figure 10

Figure 11

Figure 12

Figure 13

Figure 14

Summary of Contents for B-TIMER

Page 1: ...play the operationalstatusand doesnot release the userfrom the additional responsibility to monitor and measure the breathing air quality of the filter system in accordance with national norms e g EN 12021 This cannot be done with the B TIMER The B TIMER may only be used with BAUER compressors BAUER processing plants and original BAUER filter cartridges It has only been designed and approved for t...

Page 2: ... to indicate that the lithium battery is weakand mustbe replaced The data is saved and is not lost when the battery is changed The B TIMER is operated with the help of the entry and selection keys Error display If the temperature sensor in the device malfunctions Error 1 or Error 2 comes up at the display Figure 3 In such a case use of the B TIMER should be discontinued Send the device to the fact...

Page 3: ...splay Press the selection button to display the desired function Press the button The remaining filter capacity is displayed Figure 6 Press the button The number of operating hours lying between the point in question and service interval A 500 hours or yearly is displayed Figure 7 Press the button The number of hours remaining before service interval B 1000 hours or every two years is displayed Fi...

Page 4: ...y quantity The filter icon starts blinking Figure 13 The delivery quantity in l min can be found in the compressor s instruction manual To change the configuration hold down the button for 3 seconds after which the 1st digit starts blinking Use the button to set the desired number Use the button to accept the number in question and repeat the same procedure until all three digits have been set cor...

Reviews: