Electrical installation at the installation site
• Observe all minimum spacing requirements ( Safety instructions).
• Open the terminal box by loosening the screws.
• Lead the connection cable through to cable glands in the terminal box. Make sure not to damage
the screw seal while doing so.
• Loosen the 2 screws on the clamp.
• Make sure to remove the insulation from the wire ends (approx. 5 to 10 mm).
• Slightly loosen the screws on the terminal strips.
• Insert the wire ends into the correct terminal strips. The wires are as follows:
green-yellow (earth
conductor)
brown or black
blue
• Retighten the screws on the terminal strips.
• Reclose the terminal box using the screws.
•
Note:
The terminal box may be built differently in some models.
• Interrupt the power supply before doing any work on the LED floodlight.
Function check
• Turn on the power supply. The device should now turn on. If it does not, turn off the power supply
and check the connection again.
• For 22887322, 22908038 and 24810360: On initial operation, the motion sensor has a warm-up
time of approx. 2 to 3 minutes before it is fully functional. Briefly cover the sensor with your hand.
Setting the angle (floodlight)
• To change the beam angle, loosen the fastening bolts and adjust the floodlight as desired. Then
retighten the bolts.
Cleaning
• If necessary, clean the housing with a slightly damp cloth. Do not use any aggressive cleaning
agents.