background image

13

After Sales Support - Help Desk

Telephone: 

   

1300 663 907

Internet: 

 

           www.winplus.com.au 

Resetting the Power Meter

1.  Locate the red RESET button on the front of the energy monitor.
2.  Use a pen or a pencil to push down on the reset button for a few 

seconds.

3.  The screen will go blank.
4.  Release the RESET button – all settings will be the factory default 

settings.

Cumulative Time Display

Your Power Meter will begin to count the time that an appliance has been in 
use when it detects power usage over 2W. This will be displayed at the top 
of the LCD display. You can swap between the clock and cumulative time 
using the CLOCK button. 
When showing the cumulative time in use, DAY will be displayed on the LCD 
display to indicate days of use. This will increase when 24hrs of cumulative 
usage has occurred. 

Summary of Contents for PA39085

Page 1: ...Power Meter Model Number PA39085 After Sales Support Help Desk Telephone 1300 663 907 Internet www winplus com au INSTRUCTION MANUAL ...

Page 2: ... if the goods fail to be of acceptable quality and the failure does not amount to a major failure Power Meter Warranty Details The product is guaranteed to be free from defects in workmanship and parts for a period of 12 months from the date of purchase Defects that occur within this warranty period under normal use and care will be repaired replaced or refunded at our discretion The benefits conf...

Page 3: ...907 Internet www winplus com au Contents Warranty 2 Contents 3 Welcome 4 General Safety Instructions 5 Product Features 6 Parts List Technical Specifications 7 Product Setup 8 Product Operation 11 FAQ S 15 Repair and Refurbished Goods or Parts Notice 18 ...

Page 4: ...ce of mind that comes with purchasing a product made by one of the leading manufacturers All products brought to you by BAUHN are manufactured to the highest standards of performance and safety and as part of our philosophy of customer service and satisfaction are backed by our comprehensive 1 Year Warranty We hope you will enjoy using your purchase for many years to come Welcome ...

Page 5: ...should never be subjected to moisture or extreme temperatures Do not attempt to open the product housing There are no user serviceable parts inside this product Do not repair the unit yourself If your device is not functioning correctly disconnect the product from power and contact after sales support Supervise young children to ensure they do not play with the product Do not expose to water dust ...

Page 6: ... to hours and minutes of use After 24 hours the timer will reset to zero 2 The middle section of the LCD screen displays the cost and accumulated usage stats Press the COST button to change between accumulated energy cost electric power usage cost per kWh CO2 volume in kg and total number of days monitored 3 The bottom section of the LCD displays the current electrical parameter Press the ENERGY b...

Page 7: ...ge 0 000 9999V Current display range 0 000 9999A Frequency display range 0 000 9999Hz Rate of electricity range 0 000 99 99COST KWH Total cost used range 0 000 9999K Total energy consumed range 0 000 9999KWH Working Temperature 10 50 C Batteries 2 x LR44 Parts List Power Meter with Batteries Getting Started Guide Warranty Card Warranty Stickers Instruction Manual Energy Set Mode Cost Functions Pow...

Page 8: ...rgy used by the appliance Tip The internal batteries will allow you to set the Power Meter functions before plugging into mains power Setting the Time 1 Press and hold the CLOCK button for 3 seconds 2 With the hour digit flashing press UP repeatedly until the correct hour is reached Time is always displayed using the 24 hour clock so 2 00pm must be entered 14 00 for correct operation 3 Press the S...

Page 9: ...of 0 00 9999COST KWH Use the SET button to navigate between the digits Press the OK button to confirm your selection 6 Set the time the tariff will begin using the UP button the first 2 digits are for hours range 0 23 the second 2 digits are for minutes range 0 59 Use the SET button to navigate between minutes and hours Press OK to confirm your selection 7 Once you finish the tariff settings for T...

Page 10: ...tting the Overload Alert Threshold The Bauhn Power Meter is equipped with an overload alert feature to help identify power spikes or surges When the set threshold is exceeded OVERLOAD will flash next to ENERGY on the display Follow the below instructions to set the overload alert threshold 1 Press and hold the ENERGY button for 3 seconds to enter the OVERLOAD setting The first number will begin to...

Page 11: ...ly to cycle through the following information kWh total kWh consumed by the appliance during the monitoring period kgCO2 total CO2 emissions associated with the appliance during the monitoring period Tariff 1 cost per kWh tariff setting for Tariff code 1 off peak rate Tariff 2 cost per kWh tariff setting for Tariff code 2 peak rate Cost total cost associated with use of the appliance during the mo...

Page 12: ...ge supplied to the appliance Frequency the frequency of the power supplied shown in Hz Current the instantaneous current draw of the appliance shown in Amps Power factor the difference between the real power and apparent power useful for monitoring power supplied from an inverter Max watts maximum wattage reached during the current monitoring period Min watts minimum wattage read during the curren...

Page 13: ...SET button all settings will be the factory default settings Cumulative Time Display Your Power Meter will begin to count the time that an appliance has been in use when it detects power usage over 2W This will be displayed at the top of the LCD display You can swap between the clock and cumulative time using the CLOCK button When showing the cumulative time in use DAY will be displayed on the LCD...

Page 14: ...fault and reprogramming the information required Press down the Reset button using a paperclip or pencil and hold for 3 seconds to reset My Power Meter isn t counting the energy usage The Power Meter will not start counting energy usage unless the plugged in device is using more than 2W of energy My Power Meter isn t displaying any information Check the power outlet the power meter is connected to...

Page 15: ... by this warranty are in addition to all rights and remedies in respect of the product that the consumer has under the Competition and Consumer Act 2010 and similar state and territory laws Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable...

Page 16: ......

Reviews: