Instructions for assembly
35
GB
2.9 7-pole fan plug connector
Procedure
Connect the two 7-pole plus for the fan connection.
Open the plug retainer on the 7-pole plug (fan) of the hob
and attach the 7-pole fan mating connector (e) until it is
securely engaged. Then close the plug retainer again.
After installation, fi t the connectors on the rear panel or in
the shelf unit.
h
e
2.10 4-pole plasma fi lter plug connector (optional)
Procedure
Open the plug connections on the 4-pole plug (plasma) of
the hob and remove the protective covers. Attach the plug
to the 4-pole mating plug of the plasma fi lter (g) until it has
fi rmly engaged.
Then close the plug retainer again.
After installation, fi t the connectors on the rear panel or in
the shelf unit.
WARNING OF ELECTRICAL ENERGY!
RISK OF FATAL INJURY!
Live components have been installed
near this symbol. Covers bearing this sign
may only be removed by a certifi ed skilled
electrician.
• The electrical connection must be carried out by a
qualifi ed electrician who is authorised to carry out such
work!
• Statutory regulations and the connection specifi cations
issued by the local power supply company must be
strictly observed.
• When connecting the appliance it must be ensured that
there is a device which makes it possible to universally
disconnect it from the mains with a contact opening
width of at least 3mm. Line-protecting switches, fuses
or contactors are suitable cut-out devices. When
connecting and repairing the appliance disconnect it
from the electricity supply with one of these devices.
• The earth wire must be suffi ciently long so that if the
strain relief fails, the live wires of the connecting cable
are subjected to tension before the earth wire.
• Any superfl uous cable must be removed from the ins-
tallation area beneath the appliance.
• Make sure that the local mains voltage is the same as
the voltage on the rating label.
• Full protection against accidental contact must be en-
sured on installation.
• Attention: Incorrect connection may result in the power
electronics unit being destroyed.
• The appliance is only authorised for permanent
connection. It may not be connected with a shock-proof
plug.
Summary of Contents for CTDI K 840C NE
Page 120: ...240 613 3200 J41 400011132911 ...