5019 418 33044
DLHI 5360 - DLHI 5660
D
F
NL
E
GB
P
I
GR
PRODUCT SHEET
1. Control panel.
2. Grease filters (1 or 2 pieces).
3. Lighting unit.
4. Grease filters surround.
Removing and renewing or cleaning the
grease filter:
1. Disconnect the electrical power supply.
2. Remove the dirty grease filter by pulling the handle
first backwards and then downwards (Fig. 1).
3. After cleaning the grease filter refit in reverse
order, making sure the entire extraction surface is
covered.
Replacing bulbs
1. Disconnect the electrical power supply.
2. Remove the grease filter (Fig. 1) and the grease
filter surround (Fig. 2 - sequence a-b).
3. Remove the burnt-out bulb.
4. Use 40 W max E14 bulbs only.
5. Remount the grease filters surround.
Fitting or renewing the carbon filter:
1. Disconnect the electrical power supply.
2. Remove the grease filter (Fig. 1) and the grease
filter surround (Fig. 2 - sequence a-b).
3. If the carbon filters are already mounted (one or
two filters, depending on the model. covering the
motor protection grille) and need renewing, turn
the central handle (Fig. 3 - c) anticlockwise until
the filters release.
4. If the carbon filters are not already mounted,
locate the filters to cover the motor protection
grilles (two protection grilles - two carbon filters,
one protection grille - one carbon filter), then turn
the central handle (Fig. 3 - c) of the filters
clockwise.
5. Refit the grease filter surround and the grease
filter.
CONTROL PANEL
Light switch.
The switch has two positions
(lights OFF - lights ON).
To switch on the lights: move the switch to the
right.
Speed selector switch.
The extraction speed switch has 3 settings,
depending on the amount of steam and fumes.
To increase the extraction speed: move the
switch to the right.
Fig. 3
Fig. 1
Fig. 2
DLHI 5660
41833044.fm Page 6 Friday, December 19, 2003 10:31 AM