5019 418 33037
DNHV 5460 - 3460 - 1361 - DNI 3360
DNV 5460 - 5360 - 3360 - DNHI 3460
1.
Control panel.
2.
Extractor grilles with internal grease
filters - External grease filters
(models DNHV5460 and DNV5460 only).
3.
Lighting unit.
4.
Pull-out steam deflector.
REPLACING BULBS:
1.
Disconnect the electrical power supply.
2.
Pull out the steam deflector.
3.
Open the back grille (
a - fig. 1
)
or lighting unit (
b - fig. 1
- models DNHV5460 -
DNV 5460 only).
4.
Remove the burnt-out bulb.
Replace using 40 W max E14 bulbs only.
5.
Refit the extractor grille or lighting unit
REMOVING AND RENEWING OR
CLEANING THE GREASE FILTER:
1.
Disconnect the electrical power supply.
2.
Pull out the steam deflector.
3.
Remove the extractor grilles (
c - fig. 1
)
or grease filters (
c1/c2 - fig.2
).
4.
Release the grease filter.
5.
Remove the dirty grease filter.
6.
After the grease filter has been renewed or
cleaned (depending on model), remount in
reverse order, making sure the entire extraction
surface is covered.
FITTING OR RENEWING THE CARBON
FILTER:
1.
Disconnect the electrical power supply.
2.
Pull out the steam deflector.
3.
Remove the extractor grilles (
c - fig. 1
)
or grease filters (
c1/c2 - fig.2
).
4.
If the carbon filter is already fitted and needs
renewing, press the release buttons
(
e - fig.3
) and pull the filter out downwards.
5.
If the filters are not fitted.
d.
locate the carbon filter under the top clips
(
fig.3
).
e.
secure in place with the bottom clips (
fig. 3
).
6.
Refit the extractor grille.
CONTROL PANEL
Light switch.
The switch has two positions
(lights OFF - lights ON).
To switch on the lights: move the switch to the
right.
Speed selector switch.
The extraction speed switch has more than one
setting, depending on the amount of steam and
fumes.
To increase the extraction speed: move the
switch to the right.
FIG. 1
FIG. 2
FIG. 3