Check Engine Air Filter And Precleaner
Check air filter pre cleaner (A) and air filter (B)
before startup and every 10 hours. Remove and
clean as needed.
A
B
Check Hydraulic Hoses
1.
Skidsteer must be parked on a level surface,
park brake engaged, lift arms fully lowered,
engine stopped and key removed.
2.
Check hydraulic hoses for wear and damage
before startup and every 10 hours. Replace
worn or damaged hoses.
Check Park Brake Operation
Check park brake operation before startup and
every 10 hours or more often when conditions
warrant.
Check Hydraulic Fluid Level
1.
Skidsteer must be parked on a level surface,
park brake engaged, lift arms fully lowered,
engine stopped and key removed.
A
B
2.
Check fluid level in sight glass (A). Hydraulic
fluid should fill approximately 75% of the sight
glass. If the level is low, add enough fluid to raise
it to the proper level. AW32 is recommended
for general conditions and climates. MV22 is
recommended for colder climates.
3.
Clean the area around the filler neck of the
hydraulic tank.
4.
Remove the cap (B) from filler neck and add
hydraulic fluid as needed.
5.
Install the cap (B) on filler neck.
25